Product comparison · 2 power distribution units (pdus)

APC Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk vs HP 303264-001 power distribution unit (PDU) 2 AC outlet(s) 1U Black

Add a product
  • 6specifications compared
  • 5differ
  • 1identical
  • 13known for one product only

Key differences

The HP 303264-001 power distribution unit (PDU) 2 AC outlet(s) 1U Black has 1 U more rack capacity than the APC Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk (1U vs 0U). PDU types: Metered, Metered-by-outlet, Switched on the APC Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk, Modular on the HP 303264-001 power distribution unit (PDU) 2 AC outlet(s) 1U Black. Product colour: Blue on the APC Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk, Black on the HP 303264-001 power distribution unit (PDU) 2 AC outlet(s) 1U Black. AC outlets quantity: 24 AC outlet(s) on the APC Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk, 2 AC outlet(s) on the HP 303264-001 power distribution unit (PDU) 2 AC outlet(s) 1U Black. Nominal input voltage: 400 V on the APC Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk, 200-240 V on the HP 303264-001 power distribution unit (PDU) 2 AC outlet(s) 1U Black.

  • Rack capacity
    • Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk:0U
    • 303264-001 power distribution unit (PDU) 2 AC outlet(s) 1U Black:1U
  • Product colour
    • Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk:Blue
    • 303264-001 power distribution unit (PDU) 2 AC outlet(s) 1U Black:Black
  • AC outlets quantity
    • Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk:24 AC outlet(s)
    • 303264-001 power distribution unit (PDU) 2 AC outlet(s) 1U Black:2 AC outlet(s)
  • Nominal input voltage
    • Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk:400 V
    • 303264-001 power distribution unit (PDU) 2 AC outlet(s) 1U Black:200-240 V

Side by side

Differences highlightedShow differences only (on)
Comparison of Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V (21) C13 & (3) C19 Blue Silk, 303264-001
19 specifications
Design3 differ
PDU typesDiffersMetered, Metered-by-outlet, SwitchedModular
Rack capacityDiffers0U1U
MountingKnown for oneVerticalUnknown — not stated by the source
Product colourDiffersBlueBlack
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces1 differ
AC outlets quantityDiffers24 AC outlet(s)2 AC outlet(s)
Power plugKnown for oneIEC309Unknown — not stated by the source
AC outlet typesKnown for oneC13 coupler, C19 couplerUnknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneCurrent, Power, VoltageUnknown — not stated by the source
Outlet controlKnown for oneLock-out, Recycle, Turn off, Turn onUnknown — not stated by the source
Power1 differ
Nominal input voltageDiffers400 V200-240 V
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Output voltageKnown for one230 VUnknown — not stated by the source
Load capacityKnown for one11040 VAUnknown — not stated by the source
Maximum input current per phaseKnown for one16 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one16 AUnknown — not stated by the source
Maximum powerKnown for one11040 WUnknown — not stated by the source
AC input frequencyKnown for oneUnknown — not stated by the source50 - 60 Hz