Product comparison · 2 power distribution units (pdus)

APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black vs Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black

Add a product
  • 16specifications compared
  • 14differ
  • 2identical
  • 17known for one product only

Key differences

The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 2 U more rack capacity than the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black (2U vs 0U). The APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black has 3 more Ethernet LAN (RJ-45) ports than the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black (5 vs 2). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 36 A more maximum current than the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black (60 A vs 24 A). PDU types: Metered on the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black, Monitored on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black. Type: Single-phase on the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black, Three-phase on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black.

  • PDU types
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:Metered
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Monitored
  • Type
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:Single-phase
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Three-phase
  • Rack capacity
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:0U
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:2U
  • AC outlets quantity
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:40 AC outlet(s)
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:24 AC outlet(s)
  • Ethernet LAN (RJ-45) ports
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:5
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:2
  • Nominal input voltage
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:208 V
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:200 - 415 V
  • Maximum current
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:24 A
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:60 A
  • Nominal output voltage
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:208 V
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:240 V

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter, MN05MDR1-18I6B3-6PS56B0F10-S
33 specifications
Design3 differ
PDU typesDiffersMeteredMonitored
TypeDiffersSingle-phaseThree-phase
Rack capacityDiffers0U2U
MountingKnown for oneUnknown — not stated by the sourceHorizontal
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces3 differ
AC outlets quantityDiffers40 AC outlet(s)24 AC outlet(s)
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsDiffers52
Featuresidentical
Daisy chainKnown for oneUnknown — not stated by the sourceYes
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Management platformKnown for oneNMC3Unknown — not stated by the source
Power4 differ
Nominal input voltageDiffers208 V200 - 415 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers24 A60 A
Nominal output voltageDiffers208 V240 V
Load capacityDiffers4992 VA34500 VA
Maximum powerKnown for oneUnknown — not stated by the source34500 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Number of phasesKnown for one1Unknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceCE, cUL, UL, UKCA, RoHS, RCM, Federal Communications Commission (FCC), China RoHS
CertificationKnown for oneUKCA, CE, EN 62368-1, RoHSUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm435 mm
DepthDiffers75 mm740 mm
HeightDiffers1490 mm88 mm
WeightDiffers6.2 kg11.3 kg
Packaging dataidentical
Package weightKnown for one8.2 kgUnknown — not stated by the source
Package widthKnown for one116 mmUnknown — not stated by the source
Package depthKnown for one208 mmUnknown — not stated by the source
Package heightKnown for one1720 mmUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.