Product comparison · 2 power distribution units (pdus)

APC Rack PDU 2G, Metered, ZeroU, 17.3kW, 240V, (30) C13 & (12) C19 vs Vertiv MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black

Add a product
  • 13specifications compared
  • 11differ
  • 2identical
  • 34known for one product only

Key differences

The Vertiv MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black has 2 U more rack capacity than the APC Rack PDU 2G, Metered, ZeroU, 17.3kW, 240V, (30) C13 & (12) C19 (2U vs 0U). The APC Rack PDU 2G, Metered, ZeroU, 17.3kW, 240V, (30) C13 & (12) C19 has 6 A more maximum current than the Vertiv MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black (30 A vs 24 A). The APC Rack PDU 2G, Metered, ZeroU, 17.3kW, 240V, (30) C13 & (12) C19 has 120 V more nominal output voltage than the Vertiv MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black (240 V vs 120 V). AC outlets quantity: 42 AC outlet(s) on the APC Rack PDU 2G, Metered, ZeroU, 17.3kW, 240V, (30) C13 & (12) C19, 8 AC outlet(s) on the Vertiv MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black. AC outlet types: C13 coupler, C19 coupler on the APC Rack PDU 2G, Metered, ZeroU, 17.3kW, 240V, (30) C13 & (12) C19, NEMA 5-15R on the Vertiv MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black.

  • Rack capacity
    • Rack PDU 2G, Metered, ZeroU, 17.3kW, 240V, (30) C13 & (12) C19:0U
    • MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black:2U
  • AC outlets quantity
    • Rack PDU 2G, Metered, ZeroU, 17.3kW, 240V, (30) C13 & (12) C19:42 AC outlet(s)
    • MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black:8 AC outlet(s)
  • AC outlet types
    • Rack PDU 2G, Metered, ZeroU, 17.3kW, 240V, (30) C13 & (12) C19:C13 coupler, C19 coupler
    • MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black:NEMA 5-15R
  • Nominal input voltage
    • Rack PDU 2G, Metered, ZeroU, 17.3kW, 240V, (30) C13 & (12) C19:400 3 phases
    • MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black:120 V
  • Maximum current
    • Rack PDU 2G, Metered, ZeroU, 17.3kW, 240V, (30) C13 & (12) C19:30 A
    • MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black:24 A
  • Nominal output voltage
    • Rack PDU 2G, Metered, ZeroU, 17.3kW, 240V, (30) C13 & (12) C19:240 V
    • MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black:120 V
  • Operating temperature (T-T)
    • Rack PDU 2G, Metered, ZeroU, 17.3kW, 240V, (30) C13 & (12) C19:0 - 55 °C
    • MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black:32 - 104 °F
  • Storage temperature (T-T)
    • Rack PDU 2G, Metered, ZeroU, 17.3kW, 240V, (30) C13 & (12) C19:-25 - 65 °C
    • MP2-115A power distribution unit (PDU) 8 AC outlet(s) 2U Black:-20 - 60 °C

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8887, MP2-115A
47 specifications
Design1 differ
PDU typesKnown for oneMeteredUnknown — not stated by the source
Rack capacityDiffers0U2U
MountingKnown for oneHorizontal/VerticalUnknown — not stated by the source
Product colourBlackBlack
DisplayKnown for oneLCDUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers42 AC outlet(s)8 AC outlet(s)
AC outlet typesDiffersC13 coupler, C19 couplerNEMA 5-15R
Input connection typeKnown for oneIEC 60309 30 A 3P + N + EUnknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceNEMA 5-15P
Featuresidentical
Cable lengthKnown for one1.82 mUnknown — not stated by the source
Power3 differ
Nominal input voltageDiffers400 3 phases120 V
AC input frequency50 - 60 Hz50 - 60 Hz
Maximum currentDiffers30 A24 A
Nominal output voltageDiffers240 V120 V
Output voltageKnown for one240 VUnknown — not stated by the source
Load capacityKnown for one17300 VAUnknown — not stated by the source
Number of phasesKnown for one3Unknown — not stated by the source
Maximum input current per phaseKnown for one30 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one24 AUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Certificates1 differ
Compliance certificatesKnown for oneRoHS, REACH, WEEEUnknown — not stated by the source
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationDifferscUL listed; UL listed; VCCI class AUL1778, c-UL, & ISTA Procedure 1A listed
Operational conditions4 differ
Operating temperature (T-T)Differs0 - 55 °C32 - 104 °F
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%0 - 95%
Storage relative humidity (H-H)Differs5 - 95%0 - 95%
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Weight & dimensionsidentical
WidthKnown for one56 mmUnknown — not stated by the source
DepthKnown for one51 mmUnknown — not stated by the source
HeightKnown for one1829 mmUnknown — not stated by the source
WeightKnown for one9.6 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one13.6 kgUnknown — not stated by the source
Package widthKnown for one221 mmUnknown — not stated by the source
Package depthKnown for one112 mmUnknown — not stated by the source
Package heightKnown for one2149 mmUnknown — not stated by the source
Technical detailsidentical
Halogen freeKnown for oneNoUnknown — not stated by the source
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Removable batteryKnown for oneYesUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneIndiaUnknown — not stated by the source
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Total carbon footprint (kg of CO2e)Known for one3030.2027956064Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.