Product comparison · 2 power distribution units (pdus)

APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black vs ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black

Add a product
  • 15specifications compared
  • 13differ
  • 2identical
  • 26known for one product only

Key differences

The ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black has 1 U more rack capacity than the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black (1U vs 0U). The APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black has 4 more Ethernet LAN (RJ-45) ports than the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black (5 vs 1). The APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black has 12 A more maximum current than the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black (24 A vs 12 A). PDU types: Metered on the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black, Metered, Switched on the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black. AC outlets quantity: 40 AC outlet(s) on the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black, 8 AC outlet(s) on the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black.

  • PDU types
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:Metered
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:Metered, Switched
  • Rack capacity
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:0U
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:1U
  • AC outlets quantity
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:40 AC outlet(s)
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:8 AC outlet(s)
  • Ethernet LAN (RJ-45) ports
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:5
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:1
  • Nominal input voltage
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:208 V
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:100 - 240 V
  • Maximum current
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:24 A
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:12 A
  • Nominal output voltage
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:208 V
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:100 - 240 V
  • Load capacity
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:4992 VA
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:2400 VA

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter, PE8208AV-ATB-G
41 specifications
Design2 differ
PDU typesDiffersMeteredMetered, Switched
Rack capacityDiffers0U1U
Product colourBlackBlack
TypeKnown for oneSingle-phaseUnknown — not stated by the source
Ports & interfaces3 differ
AC outlets quantityDiffers40 AC outlet(s)8 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceNEMA 5-20P
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerNEMA 5–20R
Ethernet LAN (RJ-45) portsDiffers51
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source3 m
Security algorithmsKnown for oneUnknown — not stated by the source128-bit SSL
Password protectionKnown for oneUnknown — not stated by the sourceYes
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Firmware upgradeableKnown for oneUnknown — not stated by the sourceYes
Management protocolsKnown for oneUnknown — not stated by the sourceSNMP Manager V3
Supported network protocolsKnown for oneUnknown — not stated by the sourceTCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Ping, Telnet
Management platformKnown for oneNMC3Unknown — not stated by the source
Power4 differ
Nominal input voltageDiffers208 V100 - 240 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers24 A12 A
Nominal output voltageDiffers208 V100 - 240 V
Load capacityDiffers4992 VA2400 VA
Maximum powerKnown for oneUnknown — not stated by the source1440 W
Circuit breakerKnown for oneUnknown — not stated by the sourceYes
Number of phasesKnown for one1Unknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceFederal Communications Commission (FCC)
CertificationKnown for oneUKCA, CE, EN 62368-1, RoHSUnknown — not stated by the source
Sustainabilityidentical
Sustainability complianceKnown for oneUnknown — not stated by the sourceYes
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 50 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 60 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 80%
Weight & dimensions4 differ
WidthDiffers56 mm220.4 mm
DepthDiffers75 mm432.4 mm
HeightDiffers1490 mm44 mm
WeightDiffers6.2 kg2.84 kg
Packaging contentidentical
Cables includedKnown for oneUnknown — not stated by the sourceAC
ManualKnown for oneUnknown — not stated by the sourceYes
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Packaging dataidentical
Package weightKnown for one8.2 kgUnknown — not stated by the source
Package widthKnown for one116 mmUnknown — not stated by the source
Package depthKnown for one208 mmUnknown — not stated by the source
Package heightKnown for one1720 mmUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.