Product comparison · 2 power distribution units (pdus)

APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black vs ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software

Add a product
  • 17specifications compared
  • 14differ
  • 3identical
  • 24known for one product only

Key differences

The ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software has 1 U more rack capacity than the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black (1U vs 0U). The APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black has 8 A more maximum current than the ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software (24 A vs 16 A). The APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black has 4,612 VA more load capacity than the ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software (4992 VA vs 380 VA). PDU types: Metered on the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black, Managed, Metered, Switched on the ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software. AC outlets quantity: 40 AC outlet(s) on the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black, 8 AC outlet(s) on the ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software.

  • PDU types
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:Metered
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:Managed, Metered, Switched
  • Rack capacity
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:0U
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:1U
  • AC outlets quantity
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:40 AC outlet(s)
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:8 AC outlet(s)
  • Nominal input voltage
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:208 V
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:100 - 240 V
  • AC input frequency
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:50/60 Hz
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:50 - 60 Hz
  • Maximum current
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:24 A
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:16 A
  • Load capacity
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:4992 VA
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:380 VA
  • Width
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:56 mm
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:220.4 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter, PE6208G-ATB-G
41 specifications
Design2 differ
PDU typesDiffersMeteredManaged, Metered, Switched
TypeSingle-phaseSingle-phase
Rack capacityDiffers0U1U
MountingKnown for oneUnknown — not stated by the sourceHorizontal
Housing materialKnown for oneUnknown — not stated by the sourceMetal
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceYes
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlets quantityDiffers40 AC outlet(s)8 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceC20 coupler
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsKnown for one5Unknown — not stated by the source
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent
Outlet controlKnown for oneUnknown — not stated by the sourceTurn off, Turn on
Management platformKnown for oneNMC3Unknown — not stated by the source
Power4 differ
Nominal input voltageDiffers208 V100 - 240 V
AC input frequencyDiffers50/60 Hz50 - 60 Hz
Maximum currentDiffers24 A16 A
Load capacityDiffers4992 VA380 VA
Maximum total current draw per phaseKnown for oneUnknown — not stated by the source16 A
Maximum powerKnown for oneUnknown — not stated by the source100 W
Nominal output voltageKnown for one208 VUnknown — not stated by the source
Number of phasesKnown for one1Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 50 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 60 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 80%
Weight & dimensions4 differ
WidthDiffers56 mm220.4 mm
DepthDiffers75 mm432.4 mm
HeightDiffers1490 mm44 mm
WeightDiffers6.2 kg2.79 kg
Packaging data2 differ
Package width116 mm116 mm
Package depthDiffers208 mm499 mm
Package heightDiffers1720 mm324 mm
Package weightKnown for one8.2 kgUnknown — not stated by the source
Logistics dataidentical
Master (outer) case net weightKnown for oneUnknown — not stated by the source9.87 kg
Master (outer) case widthKnown for oneUnknown — not stated by the source388 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source519 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source348 mm
Master (outer) case gross weightKnown for oneUnknown — not stated by the source13 kg
Certificatesidentical
CertificationKnown for oneUKCA, CE, EN 62368-1, RoHSUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons