Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets vs APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets

Add a product
  • 40specifications compared
  • 14differ
  • 26identical
  • 0known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 2 U more rack capacity than the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets (2U vs 0U). The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 40 A more maximum current than the APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets (100 A vs 60 A). The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 27,600 VA more load capacity than the APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets (69000 VA vs 41400 VA). PDU types: Switched on the APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets, Switched, Metered-by-outlet on the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets. Mounting: Horizontal on the APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets, Vertical on the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets.

  • PDU types
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:Switched
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:Switched, Metered-by-outlet
  • Rack capacity
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:2U
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:0U
  • Mounting
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:Horizontal
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:Vertical
  • Input connection type
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:IEC 309 60 A
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:IEC 309 100 A
  • International Protection (IP) code
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:IP44
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:IP67
  • Maximum current
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:60 A
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:100 A
  • Load capacity
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:41400 VA
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:69000 VA
  • Width
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:443 mm
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:85 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets, NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets
40 specifications
Design3 differ
PDU typesDiffersSwitchedSwitched, Metered-by-outlet
TypeThree-phaseThree-phase
Rack capacityDiffers2U0U
MountingDiffersHorizontalVertical
Product colourBlackBlack
UpgradeableYesYes
Ports & interfaces1 differ
AC outlets quantity18 AC outlet(s)18 AC outlet(s)
Power plugIEC309IEC309
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeDiffersIEC 309 60 AIEC 309 100 A
Features1 differ
International Protection (IP) codeDiffersIP44IP67
Management featuresidentical
Management platformNMC3NMC3
Power2 differ
Nominal input voltage415 3 phases415 3 phases
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers60 A100 A
Output voltage415 V AC 3 phases415 V AC 3 phases
Load capacityDiffers41400 VA69000 VA
Number of phases33
Certificatesidentical
Compliance certificatesRoHS, REACH, WEEERoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceYesYes
Sustainabilityidentical
Doesn't containSiliconeSilicone
Operational conditionsidentical
Operating temperature (T-T)-5 - 60 °C-5 - 60 °C
Storage temperature (T-T)-20 - 60 °C-20 - 60 °C
Operating relative humidity (H-H)5 - 90%5 - 90%
Storage relative humidity (H-H)5 - 95%5 - 95%
Non-operating altitude0 - 15240 m0 - 15240 m
Weight & dimensions4 differ
WidthDiffers443 mm85 mm
DepthDiffers750 mm85 mm
HeightDiffers85 mm1980 mm
WeightDiffers16 kg20.7 kg
Packaging data3 differ
Package weightDiffers22.5 kg26.5 kg
Package widthDiffers600 mm350 mm
Package depth165 mm165 mm
Package heightDiffers940 mm2320 mm
Technical detailsidentical
Packaging recycled materialsRecycled cardboardRecycled cardboard
Preferred mounting positionno preferenceno preference
Packaging without single use plasticYesYes
SCIP number7547f066-9302-46d9-96e9-461928dd69017547f066-9302-46d9-96e9-461928dd6901
Sustainable packagingNoNo
Take-back systemNoNo