Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets vs APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets

Add a product
  • 27specifications compared
  • 4differ
  • 23identical
  • 14known for one product only

Key differences

  • PDU types
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:Metered
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Switched
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:415 3 phases
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
  • Output voltage
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:415 V AC 3 phases
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
  • Load capacity
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:41400 VA
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:17300 VA

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets, NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets
41 specifications
Design1 differ
PDU typesDiffersMeteredSwitched
TypeThree-phaseThree-phase
Rack capacity2U2U
MountingHorizontalHorizontal
Product colourBlackBlack
UpgradeableKnown for oneYesUnknown — not stated by the source
Ports & interfacesidentical
AC outlets quantity18 AC outlet(s)18 AC outlet(s)
Power plugIEC309IEC309
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeKnown for oneIEC 309 60 AUnknown — not stated by the source
Featuresidentical
International Protection (IP) codeIP44IP44
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
Power3 differ
Nominal input voltageDiffers415 3 phases208 V
AC input frequency50/60 Hz50/60 Hz
Maximum current60 A60 A
Output voltageDiffers415 V AC 3 phases208 V
Load capacityDiffers41400 VA17300 VA
Number of phasesKnown for one3Unknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHS, REACH, WEEEUnknown — not stated by the source
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
Sustainabilityidentical
Doesn't containKnown for oneSiliconeUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)-5 - 60 °C-5 - 60 °C
Storage temperature (T-T)-20 - 60 °C-20 - 60 °C
Operating relative humidity (H-H)5 - 90%5 - 90%
Storage relative humidity (H-H)5 - 95%5 - 95%
Non-operating altitude0 - 15240 m0 - 15240 m
Weight & dimensionsidentical
Width443 mm443 mm
Depth750 mm750 mm
Height85 mm85 mm
Weight15.7 kg15.7 kg
Packaging dataidentical
Package weight22.2 kg22.2 kg
Package width600 mm600 mm
Package depth165 mm165 mm
Package height940 mm940 mm
Technical detailsidentical
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Packaging without single use plasticKnown for oneYesUnknown — not stated by the source
SCIP numberKnown for one7547f066-9302-46d9-96e9-461928dd6901Unknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.