Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets vs StarTech.com 12-Outlet Rackmount PDU, 1U Server Power Strip with Wide-Spaced Right-Angle Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets

Add a product
  • 19specifications compared
  • 18differ
  • 1identical
  • 37known for one product only

Key differences

The StarTech.com 12-Outlet Rackmount PDU, 1U Server Power Strip with Wide-Spaced Right-Angle Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets has 1 U more rack capacity than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets (1U vs 0U). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 85 A more maximum current than the StarTech.com 12-Outlet Rackmount PDU, 1U Server Power Strip with Wide-Spaced Right-Angle Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets (100 A vs 15 A). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 67,500 VA more load capacity than the StarTech.com 12-Outlet Rackmount PDU, 1U Server Power Strip with Wide-Spaced Right-Angle Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets (69000 VA vs 1500 VA). PDU types: Metered on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, Basic on the StarTech.com 12-Outlet Rackmount PDU, 1U Server Power Strip with Wide-Spaced Right-Angle Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets. AC outlets quantity: 18 AC outlet(s) on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, 12 AC outlet(s) on the StarTech.com 12-Outlet Rackmount PDU, 1U Server Power Strip with Wide-Spaced Right-Angle Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets.

  • PDU types
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:Metered
    • 12-Outlet Rackmount PDU, 1U Server Power Strip with Wide-Spaced Right-Angle Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:Basic
  • Rack capacity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:0U
    • 12-Outlet Rackmount PDU, 1U Server Power Strip with Wide-Spaced Right-Angle Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:1U
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:18 AC outlet(s)
    • 12-Outlet Rackmount PDU, 1U Server Power Strip with Wide-Spaced Right-Angle Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:12 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:IEC309
    • 12-Outlet Rackmount PDU, 1U Server Power Strip with Wide-Spaced Right-Angle Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:NEMA 5-15P
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 3 phases
    • 12-Outlet Rackmount PDU, 1U Server Power Strip with Wide-Spaced Right-Angle Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:120 V
  • Maximum current
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:100 A
    • 12-Outlet Rackmount PDU, 1U Server Power Strip with Wide-Spaced Right-Angle Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:15 A
  • Output voltage
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 V AC 3 phases
    • 12-Outlet Rackmount PDU, 1U Server Power Strip with Wide-Spaced Right-Angle Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:125 V
  • Load capacity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:69000 VA
    • 12-Outlet Rackmount PDU, 1U Server Power Strip with Wide-Spaced Right-Angle Ports, Mounted Power Distribution Unit for 19-Inch Racks and Cabinets:1500 VA

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, 1215B8H-RACK-PDU-RA
56 specifications
Design2 differ
PDU typesDiffersMeteredBasic
TypeKnown for oneThree-phaseUnknown — not stated by the source
Rack capacityDiffers0U1U
MountingKnown for oneVerticalUnknown — not stated by the source
Product colourBlackBlack
UpgradeableKnown for oneYesUnknown — not stated by the source
Housing materialKnown for oneUnknown — not stated by the sourceSteel
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers18 AC outlet(s)12 AC outlet(s)
Power plugDiffersIEC309NEMA 5-15P
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerNEMA 5-15R
Input connection typeKnown for oneIEC 309 100 AUnknown — not stated by the source
Featuresidentical
International Protection (IP) codeKnown for oneIP67Unknown — not stated by the source
Cable lengthKnown for oneUnknown — not stated by the source2.4 m
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
Power4 differ
Nominal input voltageDiffers415 3 phases120 V
Maximum currentDiffers100 A15 A
Output voltageDiffers415 V AC 3 phases125 V
Load capacityDiffers69000 VA1500 VA
Number of phasesKnown for one3Unknown — not stated by the source
Nominal output voltageKnown for oneUnknown — not stated by the source120 V
Maximum total current draw per phaseKnown for oneUnknown — not stated by the source15 A
Circuit breakerKnown for oneUnknown — not stated by the sourceYes
Certificates1 differ
Compliance certificatesDiffersRoHS, REACH, WEEERoHS, Trade Agreements Act (TAA)
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
Sustainabilityidentical
Doesn't containKnown for oneSiliconeUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers59 mm95.2 mm
DepthDiffers87 mm477.2 mm
HeightDiffers1750 mm43.3 mm
WeightDiffers18.8 kg1.62 kg
Packaging data4 differ
Package weightDiffers24.6 kg2.1 kg
Package widthDiffers350 mm515 mm
Package depthDiffers165 mm235 mm
Package heightDiffers1980 mm52 mm
Technical detailsidentical
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Packaging without single use plasticKnown for oneYesUnknown — not stated by the source
SCIP numberKnown for one7547f066-9302-46d9-96e9-461928dd6901Unknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Master (outer) case widthKnown for oneUnknown — not stated by the source528 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source350 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source250 mm
Products per master (outer) caseKnown for oneUnknown — not stated by the source4 pc(s)
Packaging contentidentical
ManualKnown for oneUnknown — not stated by the sourceYes
Number of screw nutsKnown for oneUnknown — not stated by the source4
Number of screwsKnown for oneUnknown — not stated by the source4
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Screw nuts includedKnown for oneUnknown — not stated by the sourceYes
Screws includedKnown for oneUnknown — not stated by the sourceYes