Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets vs ATEN 2-Outlet Eco PDU Power Controller

Add a product
  • 20specifications compared
  • 18differ
  • 2identical
  • 38known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 90 A more maximum current than the ATEN 2-Outlet Eco PDU Power Controller (100 A vs 10 A). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 66,600 VA more load capacity than the ATEN 2-Outlet Eco PDU Power Controller (69000 VA vs 2400 VA). The ATEN 2-Outlet Eco PDU Power Controller has 68.8 mm more width than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets (127.8 mm vs 59 mm). PDU types: Metered on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, Managed on the ATEN 2-Outlet Eco PDU Power Controller. AC outlets quantity: 18 AC outlet(s) on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, 2 AC outlet(s) on the ATEN 2-Outlet Eco PDU Power Controller.

  • PDU types
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:Metered
    • 2-Outlet Eco PDU Power Controller:Managed
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:18 AC outlet(s)
    • 2-Outlet Eco PDU Power Controller:2 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:IEC309
    • 2-Outlet Eco PDU Power Controller:C14 coupler
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 3 phases
    • 2-Outlet Eco PDU Power Controller:100 - 240 V
  • Maximum current
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:100 A
    • 2-Outlet Eco PDU Power Controller:10 A
  • Load capacity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:69000 VA
    • 2-Outlet Eco PDU Power Controller:2400 VA
  • Operating temperature (T-T)
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:-5 - 60 °C
    • 2-Outlet Eco PDU Power Controller:0 - 50 °C
  • Operating relative humidity (H-H)
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:5 - 90%
    • 2-Outlet Eco PDU Power Controller:0 - 80%

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets, PE4102G
58 specifications
Design1 differ
PDU typesDiffersMeteredManaged
TypeKnown for oneThree-phaseUnknown — not stated by the source
Rack capacityKnown for one0UUnknown — not stated by the source
MountingKnown for oneVerticalUnknown — not stated by the source
Product colourBlackBlack
UpgradeableKnown for oneYesUnknown — not stated by the source
Rack mountingKnown for oneUnknown — not stated by the sourceYes
Mounting typeKnown for oneUnknown — not stated by the sourceDesk/Wall
Ports & interfaces3 differ
AC outlets quantityDiffers18 AC outlet(s)2 AC outlet(s)
Power plugDiffersIEC309C14 coupler
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler
Input connection typeKnown for oneIEC 309 100 AUnknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
Featuresidentical
International Protection (IP) codeKnown for oneIP67Unknown — not stated by the source
Cable lengthKnown for oneUnknown — not stated by the source3 m
Password protectionKnown for oneUnknown — not stated by the sourceYes
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
Supported network protocolsKnown for oneUnknown — not stated by the sourceTCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, ARP, NTP, DNS, SNMP V1&V2&V3
Power3 differ
Nominal input voltageDiffers415 3 phases100 - 240 V
Maximum currentDiffers100 A10 A
Output voltageKnown for one415 V AC 3 phasesUnknown — not stated by the source
Load capacityDiffers69000 VA2400 VA
Number of phasesKnown for one3Unknown — not stated by the source
AC input frequencyKnown for oneUnknown — not stated by the source50 - 60 Hz
Nominal output voltageKnown for oneUnknown — not stated by the source100 - 240 V
Certificates1 differ
Compliance certificatesDiffersRoHS, REACH, WEEELow Voltage Directive (LVD), CE, Electromagnetic Compatibility (EMC)
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
Sustainabilityidentical
Doesn't containKnown for oneSiliconeUnknown — not stated by the source
Operational conditions2 differ
Operating temperature (T-T)Differs-5 - 60 °C0 - 50 °C
Storage temperature (T-T)-20 - 60 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 90%0 - 80%
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers59 mm127.8 mm
DepthDiffers87 mm170 mm
HeightDiffers1750 mm44 mm
WeightDiffers18.8 kg980 g
Packaging data4 differ
Package weightDiffers24.6 kg1.27 kg
Package widthDiffers350 mm95 mm
Package depthDiffers165 mm265 mm
Package heightDiffers1980 mm220 mm
Package volumeKnown for oneUnknown — not stated by the source5550.101932032 cm³
Technical detailsidentical
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Packaging without single use plasticKnown for oneYesUnknown — not stated by the source
SCIP numberKnown for one7547f066-9302-46d9-96e9-461928dd6901Unknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Country of originKnown for oneUnknown — not stated by the sourceChina
Master (outer) case net weightKnown for oneUnknown — not stated by the source4.9 kg
Master (outer) case widthKnown for oneUnknown — not stated by the source232 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source500 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source283 mm
Master (outer) case gross weightKnown for oneUnknown — not stated by the source6.92 kg
Master (outer) case volumeKnown for oneUnknown — not stated by the source32819.225200128 cm³
Packaging contentidentical
Cables includedKnown for oneUnknown — not stated by the sourceAC
ManualKnown for oneUnknown — not stated by the sourceYes

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.