Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets vs Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black

Add a product
  • 15specifications compared
  • 13differ
  • 2identical
  • 18known for one product only

Key differences

The Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black has 1 U more rack capacity than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (1U vs 0U). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 70 A more maximum current than the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black (100 A vs 30 A). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 23,100 VA more load capacity than the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black (28800 VA vs 5700 VA). PDU types: Metered on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, Basic on the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black. Mounting: Vertical on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, Horizontal on the Vertiv MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black.

  • PDU types
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Metered
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:Basic
  • Rack capacity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:0U
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:1U
  • Mounting
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Vertical
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:Horizontal
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:30 AC outlet(s)
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:16 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:IEC 60309
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:NEMA L14-30P
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:100 - 240 V
  • Maximum current
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:100 A
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:30 A
  • Load capacity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:28800 VA
    • MN00X1R1-16MCQ9-3TL14A0A10-S power distribution unit (PDU) 16 AC outlet(s) 1U Black:5700 VA

Side by side

Differences highlightedShow differences only (on)
Comparison of NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, MN00X1R1-16MCQ9-3TL14A0A10-S
33 specifications
Design3 differ
PDU typesDiffersMeteredBasic
TypeKnown for oneThree-phaseUnknown — not stated by the source
Rack capacityDiffers0U1U
MountingDiffersVerticalHorizontal
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers30 AC outlet(s)16 AC outlet(s)
Power plugDiffersIEC 60309NEMA L14-30P
AC outlet typesDiffersC15 coupler, C13 coupler, C19 coupler, C21 couplerNEMA 5-20R, C13 coupler
Featuresidentical
International Protection (IP) codeKnown for oneIP67Unknown — not stated by the source
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
Power3 differ
Nominal input voltageDiffers208 V100 - 240 V
Maximum currentDiffers100 A30 A
Output voltageKnown for one208 VUnknown — not stated by the source
Load capacityDiffers28800 VA5700 VA
Nominal output voltageKnown for oneUnknown — not stated by the source208 V
Maximum powerKnown for oneUnknown — not stated by the source5700 W
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 60 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm50.8 mm
DepthDiffers75 mm50.8 mm
HeightDiffers1900 mm1682.7 mm
WeightDiffers14 kg6.8 kg
Packaging dataidentical
Package weightKnown for one19.8 kgUnknown — not stated by the source
Package widthKnown for one350 mmUnknown — not stated by the source
Package depthKnown for one165 mmUnknown — not stated by the source
Package heightKnown for one2110 mmUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceTrade Agreements Act (TAA), UL, cUL, RoHS

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.