Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets vs CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black

Add a product
  • 24specifications compared
  • 23differ
  • 1identical
  • 16known for one product only

Key differences

The CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black has 1 U more rack capacity than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (1U vs 0U). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 88 V more nominal input voltage than the CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black (208 V vs 120 V). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 85 A more maximum current than the CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black (100 A vs 15 A). PDU types: Metered on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, Switched on the CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black. Type: Three-phase on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, Single-phase on the CyberPower PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black.

  • PDU types
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Metered
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:Switched
  • Type
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Three-phase
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:Single-phase
  • Rack capacity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:0U
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:1U
  • Mounting
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Vertical
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:Horizontal
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:30 AC outlet(s)
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:16 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:IEC 60309
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:NEMA 5-15P
  • Management platform
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:NMC3
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:SNMP
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V
    • PDU41021 power distribution unit (PDU) 16 AC outlet(s) 1U Black:120 V

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, PDU41021
40 specifications
Design4 differ
PDU typesDiffersMeteredSwitched
TypeDiffersThree-phaseSingle-phase
Rack capacityDiffers0U1U
MountingDiffersVerticalHorizontal
Housing materialKnown for oneUnknown — not stated by the sourceMetal
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLCD
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers30 AC outlet(s)16 AC outlet(s)
Power plugDiffersIEC 60309NEMA 5-15P
AC outlet typesDiffersC15 coupler, C13 coupler, C19 coupler, C21 couplerNEMA 5-15R
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Featuresidentical
Daisy chainKnown for oneUnknown — not stated by the sourceYes
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source3.7 m
International Protection (IP) codeKnown for oneIP67Unknown — not stated by the source
Management features1 differ
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Energy, Temperature, Humidity, Voltage, Alarm
Management platformDiffersNMC3SNMP
Supported network protocolsKnown for oneUnknown — not stated by the sourceIPv4/v6, SNMPv1/v3, HTTP/HTTPs, TCP/IP, UDP, DHCP, NTP, DNS, SMTP, SSH, SSL, TLS, Telnet, FTP, and Syslog, RADIUS, LDAP, LDAPS, Windows AD
Power3 differ
Nominal input voltageDiffers208 V120 V
AC input frequencyDiffers50/60 Hz50-60 Hz
Maximum currentDiffers100 A15 A
Nominal output voltageKnown for oneUnknown — not stated by the source100-120 V
Output voltageKnown for one208 VUnknown — not stated by the source
Load capacityKnown for one28800 VAUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceUL, Federal Communications Commission (FCC), RoHS
Operational conditions4 differ
Operating temperature (T-T)Differs-5 - 60 °C32 - 140 °F
Storage temperature (T-T)Differs-20 - 60 °C-15 - 65 °C
Operating relative humidity (H-H)Differs5 - 90%0 - 95%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3500 m
Non-operating altitudeDiffers0 - 15240 m0 - 14999 m
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm433 mm
DepthDiffers75 mm215 mm
HeightDiffers1900 mm44 mm
WeightDiffers14 kg3.81 kg
Packaging data4 differ
Package weightDiffers19.8 kg5.53 kg
Package widthDiffers350 mm552.5 mm
Package depthDiffers165 mm406.4 mm
Package heightDiffers2110 mm127 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.