Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets vs ATEN 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software

Add a product
  • 22specifications compared
  • 20differ
  • 2identical
  • 20known for one product only

Key differences

The ATEN 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software has 1 U more rack capacity than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (1U vs 0U). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 84 A more maximum current than the ATEN 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software (100 A vs 16 A). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 25,120 VA more load capacity than the ATEN 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software (28800 VA vs 3680 VA). PDU types: Metered on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, Metered, Switched on the ATEN 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software. Mounting: Vertical on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, Horizontal on the ATEN 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software.

  • PDU types
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Metered
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:Metered, Switched
  • Rack capacity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:0U
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:1U
  • Mounting
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Vertical
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:Horizontal
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:30 AC outlet(s)
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:8 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:IEC 60309
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:C20 coupler
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:100 - 240 V
  • AC input frequency
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:50/60 Hz
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:50 - 60 Hz
  • Maximum current
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:100 A
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:16 A

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, PE8208G-ATB-G
42 specifications
Design3 differ
PDU typesDiffersMeteredMetered, Switched
Rack capacityDiffers0U1U
MountingDiffersVerticalHorizontal
Product colourBlackBlack
On/off switchKnown for oneUnknown — not stated by the sourceYes
TypeKnown for oneThree-phaseUnknown — not stated by the source
Ports & interfaces3 differ
AC outlets quantityDiffers30 AC outlet(s)8 AC outlet(s)
Power plugDiffersIEC 60309C20 coupler
AC outlet typesDiffersC15 coupler, C13 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Featuresidentical
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source3 m
International Protection (IP) codeKnown for oneIP67Unknown — not stated by the source
Power4 differ
Nominal input voltageDiffers208 V100 - 240 V
AC input frequencyDiffers50/60 Hz50 - 60 Hz
Maximum currentDiffers100 A16 A
Nominal output voltageKnown for oneUnknown — not stated by the source100 - 240 V
Load capacityDiffers28800 VA3680 VA
Maximum powerKnown for oneUnknown — not stated by the source100 W
Output voltageKnown for one208 VUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceCE TUV-CB CE-LVD GOST
Operational conditions2 differ
Operating temperature (T-T)Differs-5 - 60 °C0 - 50 °C
Storage temperature (T-T)-20 - 60 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 90%0 - 80%
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm220.4 mm
DepthDiffers75 mm432.4 mm
HeightDiffers1900 mm44 mm
WeightDiffers14 kg3.38 kg
Packaging contentidentical
Cables includedKnown for oneUnknown — not stated by the sourceAC
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Packaging data4 differ
Package weightDiffers19.8 kg4.04 kg
Package widthDiffers350 mm116 mm
Package depthDiffers165 mm499 mm
Package heightDiffers2110 mm324 mm
Logistics dataidentical
Master (outer) case net weightKnown for oneUnknown — not stated by the source10.1 kg
Master (outer) case widthKnown for oneUnknown — not stated by the source388 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source519 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source348 mm
Master (outer) case gross weightKnown for oneUnknown — not stated by the source13.3 kg
Products per master (outer) caseKnown for oneUnknown — not stated by the source3 pc(s)
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.