Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets vs APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets

Add a product
  • 27specifications compared
  • 12differ
  • 15identical
  • 14known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 40,200 VA more load capacity than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (69000 VA vs 28800 VA). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 3 mm more width than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (59 mm vs 56 mm). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 12 mm more depth than the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets (87 mm vs 75 mm). AC outlets quantity: 30 AC outlet(s) on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, 18 AC outlet(s) on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets. Power plug: IEC 60309 on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, IEC309 on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets.

  • AC outlets quantity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:30 AC outlet(s)
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:18 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:IEC 60309
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:IEC309
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 3 phases
  • Output voltage
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 V AC 3 phases
  • Load capacity
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:28800 VA
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:69000 VA
  • Width
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:56 mm
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:59 mm
  • Depth
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:75 mm
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:87 mm
  • Height
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:1900 mm
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:1750 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets, NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets
41 specifications
Designidentical
UpgradeableKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers30 AC outlet(s)18 AC outlet(s)
Power plugDiffersIEC 60309IEC309
AC outlet typesDiffersC15 coupler, C13 coupler, C19 coupler, C21 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 309 100 A
Power3 differ
Nominal input voltageDiffers208 V415 3 phases
Output voltageDiffers208 V415 V AC 3 phases
Load capacityDiffers28800 VA69000 VA
Number of phasesKnown for oneUnknown — not stated by the source3
AC input frequencyKnown for one50/60 HzUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneUnknown — not stated by the sourceYes
Sustainabilityidentical
Doesn't containKnown for oneUnknown — not stated by the sourceSilicone
Weight & dimensions4 differ
WidthDiffers56 mm59 mm
DepthDiffers75 mm87 mm
HeightDiffers1900 mm1750 mm
WeightDiffers14 kg18.8 kg
Packaging data2 differ
Package weightDiffers19.8 kg24.6 kg
Package heightDiffers2110 mm1980 mm
Technical detailsidentical
Packaging recycled materialsKnown for oneUnknown — not stated by the sourceRecycled cardboard
Preferred mounting positionKnown for oneUnknown — not stated by the sourceno preference
Packaging without single use plasticKnown for oneUnknown — not stated by the sourceYes
SCIP numberKnown for oneUnknown — not stated by the source7547f066-9302-46d9-96e9-461928dd6901
Sustainable packagingKnown for oneUnknown — not stated by the sourceNo
Take-back systemKnown for oneUnknown — not stated by the sourceNo
Logistics dataidentical
Customs product code (TARIC)Known for oneUnknown — not stated by the source8537109899

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.