Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet vs APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet

Add a product
  • 38specifications compared
  • 12differ
  • 26identical
  • 0known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet has 30 A more maximum current than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet (60 A vs 30 A). The APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet has 10 V more output voltage than the APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet (240 V vs 230 V). The APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet has 17,300 VA more load capacity than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet (34600 VA vs 17300 VA). AC outlets quantity: 48 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet, 42 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet. Input connection type: IEC 60309 30 A 3P + N + PE on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet, IEC 60309 32 A 2P + PE on the APC NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet.

  • AC outlets quantity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:48 AC outlet(s)
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:42 AC outlet(s)
  • Input connection type
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:IEC 60309 30 A 3P + N + PE
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:IEC 60309 32 A 2P + PE
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:415 3 phases; 400 3 phases
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 1 phase
  • Maximum current
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:30 A
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:60 A
  • Output voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:240 V
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 V
  • Load capacity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:17300 VA
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:34600 VA
  • Number of phases
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:3
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:1
  • Height
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:1780 mm
    • NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:1490 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet, NetShelter Rack PDU Advanced Gen 2, Switched, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet
38 specifications
Designidentical
PDU typesMeteredMetered
TypeThree-phaseThree-phase
Rack capacity0U0U
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers48 AC outlet(s)42 AC outlet(s)
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) ports55
USB ports quantity11
Input connection typeDiffersIEC 60309 30 A 3P + N + PEIEC 60309 32 A 2P + PE
Featuresidentical
Cable length3 m3 m
Management featuresidentical
Management platformNMC3NMC3
Power5 differ
Nominal input voltageDiffers415 3 phases; 400 3 phases230 1 phase
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers30 A60 A
Nominal output voltage400 V400 V
Output voltageDiffers240 V230 V
Load capacityDiffers17300 VA34600 VA
Number of phasesDiffers31
Battery replacement accessibilityNon-removableNon-removable
Certificates1 differ
Compliance certificatesRoHS, REACH, WEEERoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceYesYes
CertificationDiffersUL 62368-1 CSA C22.2 No 62368-1 FCC part 15 Subpart B CE EN 62368-1UKCA
Weight & dimensions2 differ
Width56 mm56 mm
Depth75 mm75 mm
HeightDiffers1780 mm1490 mm
WeightDiffers8.4 kg7.4 kg
Packaging data2 differ
Package weightDiffers11.4 kg17 kg
Package width132 mm132 mm
Package depth262 mm262 mm
Package heightDiffers1980 mm2110 mm
Technical detailsidentical
Preferred mounting positionno preferenceno preference
Removable batteryNoNo
Packaging without single use plasticNoNo
SCIP number31346aed-552c-4a16-81d9-e683a383b6da31346aed-552c-4a16-81d9-e683a383b6da
Sustainable packagingNoNo
Take-back systemNoNo
Logistics dataidentical
Country of originUnited StatesUnited States
Customs product code (TARIC)85371098998537109899

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons