Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet vs Vertiv Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black

Add a product
  • 18specifications compared
  • 13differ
  • 5identical
  • 27known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet has 4 more Ethernet LAN (RJ-45) ports than the Vertiv Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black (5 vs 1). The Vertiv Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black has 0.05 m more cable length than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet (3.05 m vs 3 m). The Vertiv Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black has 60 A more maximum current than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet (80 A vs 20 A). PDU types: Metered on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet, Switched on the Vertiv Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black. AC outlets quantity: 40 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet, 24 AC outlet(s) on the Vertiv Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black.

  • PDU types
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:Metered
    • Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:Switched
  • AC outlets quantity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:40 AC outlet(s)
    • Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:24 AC outlet(s)
  • Ethernet LAN (RJ-45) ports
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:5
    • Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:1
  • Cable length
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:3 m
    • Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:3.05 m
  • Nominal input voltage
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:415 3 phases; 400 3 phases
    • Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:208 V
  • Maximum current
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:20 A
    • Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:80 A
  • Load capacity
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:11500 VA
    • Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:208 VA
  • Width
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:56 mm
    • Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:97 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet, JMNS5MIZ1-24CF18-8HW15A9BXX-S
45 specifications
Design1 differ
PDU typesDiffersMeteredSwitched
TypeThree-phaseThree-phase
Rack capacity0U0U
Product colourBlackBlack
MountingKnown for oneUnknown — not stated by the sourceVertical
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces3 differ
AC outlets quantityDiffers40 AC outlet(s)24 AC outlet(s)
AC outlet typesDiffersC13 coupler, C15 coupler, C19 coupler, C21 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsDiffers51
USB ports quantity11
Input connection typeKnown for oneIEC 60309 20 A 3P + N + PEUnknown — not stated by the source
Serial ports quantityKnown for oneUnknown — not stated by the source1
Features1 differ
Cable lengthDiffers3 m3.05 m
Reset buttonKnown for oneUnknown — not stated by the sourceYes
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Management featuresidentical
Management platformKnown for oneNMC3Unknown — not stated by the source
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power3 differ
Nominal input voltageDiffers415 3 phases; 400 3 phases208 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers20 A80 A
Nominal output voltageKnown for one400 VUnknown — not stated by the source
Output voltageKnown for one240 VUnknown — not stated by the source
Load capacityDiffers11500 VA208 VA
Number of phasesKnown for one3Unknown — not stated by the source
Battery replacement accessibilityKnown for oneNon-removableUnknown — not stated by the source
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificates1 differ
Compliance certificatesKnown for oneRoHS, REACH, WEEEUnknown — not stated by the source
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationDiffersUKCAUL & c-UL Listed 62368-1 RoHS Compliant FCC Part 15 Class A Conformance
Weight & dimensions4 differ
WidthDiffers56 mm97 mm
DepthDiffers55 mm76 mm
HeightDiffers1490 mm1683 mm
WeightDiffers5.7 kg9.98 kg
Packaging dataidentical
Package weightKnown for one8.2 kgUnknown — not stated by the source
Package widthKnown for one116 mmUnknown — not stated by the source
Package depthKnown for one208 mmUnknown — not stated by the source
Package heightKnown for one1720 mmUnknown — not stated by the source
Technical detailsidentical
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Removable batteryKnown for oneNoUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
SCIP numberKnown for one31346aed-552c-4a16-81d9-e683a383b6daUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source10 - 45 °C

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.