Product comparison · 2 power distribution units (pdus)

APC IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 680cm vs APC PDM2316IEC-3P30R-3 power distribution unit (PDU) 3 AC outlet(s) Black

Add a product
  • 27specifications compared
  • 13differ
  • 14identical
  • 3known for one product only

Key differences

  • AC outlets quantity
    • IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 680cm:1 AC outlet(s)
    • PDM2316IEC-3P30R-3 power distribution unit (PDU) 3 AC outlet(s) Black:3 AC outlet(s)
  • Output connections
    • IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 680cm:1 x IEC 309
    • PDM2316IEC-3P30R-3 power distribution unit (PDU) 3 AC outlet(s) Black:3 x IEC 309
  • Nominal output voltage
    • IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 680cm:230-400 V
    • PDM2316IEC-3P30R-3 power distribution unit (PDU) 3 AC outlet(s) Black:230 V
  • Maximum input current per phase
    • IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 680cm:63 A
    • PDM2316IEC-3P30R-3 power distribution unit (PDU) 3 AC outlet(s) Black:16 A
  • Maximum total current draw per phase
    • IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 680cm:63 A
    • PDM2316IEC-3P30R-3 power distribution unit (PDU) 3 AC outlet(s) Black:16 A
  • Width
    • IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 680cm:267 mm
    • PDM2316IEC-3P30R-3 power distribution unit (PDU) 3 AC outlet(s) Black:432 mm
  • Depth
    • IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 680cm:305 mm
    • PDM2316IEC-3P30R-3 power distribution unit (PDU) 3 AC outlet(s) Black:406 mm
  • Height
    • IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 680cm:152 mm
    • PDM2316IEC-3P30R-3 power distribution unit (PDU) 3 AC outlet(s) Black:254 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 680cm, PDM2316IEC-3P30R-3
30 specifications
Ports & interfaces2 differ
AC outlets quantityDiffers1 AC outlet(s)3 AC outlet(s)
Output connectionsDiffers1 x IEC 3093 x IEC 309
Featuresidentical
Cable lengthKnown for one6.8 mUnknown — not stated by the source
Power3 differ
Nominal output voltageDiffers230-400 V230 V
Output voltageKnown for one230 - 400 VUnknown — not stated by the source
Maximum input current per phaseDiffers63 A16 A
Maximum total current draw per phaseDiffers63 A16 A
Weight & dimensions4 differ
WidthDiffers267 mm432 mm
DepthDiffers305 mm406 mm
HeightDiffers152 mm254 mm
WeightDiffers21.8 kg6.8 kg
Packaging data4 differ
Package weightDiffers23.6 kg7.7 kg
Package widthDiffers508 mm432 mm
Package depthDiffers508 mm406 mm
Package heightDiffers229 mm254 mm
Logistics dataidentical
Warranty periodKnown for one1 year(s)Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.