Product comparison · 2 power distribution units (pdus)

APC IT Power Distribution Module 3 Pole 4 Wire 60A IEC309 320cm vs APC IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 800cm

Add a product
  • 21specifications compared
  • 15differ
  • 6identical
  • 8known for one product only

Key differences

  • Cable length
    • IT Power Distribution Module 3 Pole 4 Wire 60A IEC309 320cm:3.2 m
    • IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 800cm:8 m
  • Nominal input voltage
    • IT Power Distribution Module 3 Pole 4 Wire 60A IEC309 320cm:208 V
    • IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 800cm:400 V
  • AC input frequency
    • IT Power Distribution Module 3 Pole 4 Wire 60A IEC309 320cm:60 Hz
    • IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 800cm:50 Hz
  • Nominal output voltage
    • IT Power Distribution Module 3 Pole 4 Wire 60A IEC309 320cm:208 V
    • IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 800cm:230-400 V
  • Maximum input current per phase
    • IT Power Distribution Module 3 Pole 4 Wire 60A IEC309 320cm:60 A
    • IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 800cm:63 A
  • Maximum total current draw per phase
    • IT Power Distribution Module 3 Pole 4 Wire 60A IEC309 320cm:60 A
    • IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 800cm:63 A
  • Certification
    • IT Power Distribution Module 3 Pole 4 Wire 60A IEC309 320cm:UL
    • IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 800cm:CE,VDE
  • Width
    • IT Power Distribution Module 3 Pole 4 Wire 60A IEC309 320cm:445 mm
    • IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 800cm:267 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of IT Power Distribution Module 3 Pole 4 Wire 60A IEC309 320cm, IT Power Distribution Module 3 Pole 5 Wire 63A IEC309 800cm
29 specifications
Designidentical
Product colourKnown for oneGreyUnknown — not stated by the source
DisplayKnown for oneLCDUnknown — not stated by the source
Features1 differ
Cable lengthDiffers3.2 m8 m
Power5 differ
Nominal input voltageDiffers208 V400 V
AC input frequencyDiffers60 Hz50 Hz
Nominal output voltageDiffers208 V230-400 V
Maximum input current per phaseDiffers60 A63 A
Maximum total current draw per phaseDiffers60 A63 A
Certificates1 differ
CertificationDiffersULCE,VDE
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 30 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-15 - 40 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3000 m
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 4500 m
Weight & dimensions4 differ
WidthDiffers445 mm267 mm
DepthDiffers406 mm305 mm
HeightDiffers127 mm152 mm
WeightDiffers4.09 kg25 kg
Packaging data4 differ
Package weightDiffers4.64 kg26.8 kg
Package widthDiffers445 mm508 mm
Package depthDiffers406 mm508 mm
Package heightDiffers127 mm229 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons