Product comparison · 2 power distribution units (pdus)

APC InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless vs APC Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Add a product
  • 16specifications compared
  • 14differ
  • 2identical
  • 6known for one product only

Key differences

  • Nominal input voltage
    • InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless:400 V
    • Rack PDU, Metered, Zero U, 10A, 230V, (16) C13:230 V
  • Maximum input current per phase
    • InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless:173 A
    • Rack PDU, Metered, Zero U, 10A, 230V, (16) C13:10 A
  • Operating temperature (T-T)
    • InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless:0 - 40 °C
    • Rack PDU, Metered, Zero U, 10A, 230V, (16) C13:-5 - 45 °C
  • Storage temperature (T-T)
    • InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless:-15 - 45 °C
    • Rack PDU, Metered, Zero U, 10A, 230V, (16) C13:-25 - 65 °C
  • Operating relative humidity (H-H)
    • InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless:0 - 95%
    • Rack PDU, Metered, Zero U, 10A, 230V, (16) C13:5 - 95%
  • Storage relative humidity (H-H)
    • InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless:0 - 95%
    • Rack PDU, Metered, Zero U, 10A, 230V, (16) C13:5 - 95%
  • Width
    • InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless:737 mm
    • Rack PDU, Metered, Zero U, 10A, 230V, (16) C13:56 mm
  • Depth
    • InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless:864 mm
    • Rack PDU, Metered, Zero U, 10A, 230V, (16) C13:44 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless, Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
22 specifications
Ports & interfacesidentical
Input connection typeKnown for oneUnknown — not stated by the sourceIEC-320 C14
Output connectionsKnown for oneUnknown — not stated by the source(16) IEC 320 C13
I/O portsKnown for oneUnknown — not stated by the source(16) IEC 320 C13
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source0.0305 m
Power2 differ
Nominal input voltageDiffers400 V230 V
Nominal output voltageKnown for oneUnknown — not stated by the source230 V
Maximum input current per phaseDiffers173 A10 A
Maximum total current draw per phaseKnown for oneUnknown — not stated by the source10 A
Operational conditions4 differ
Operating temperature (T-T)Differs0 - 40 °C-5 - 45 °C
Storage temperature (T-T)Differs-15 - 45 °C-25 - 65 °C
Operating relative humidity (H-H)Differs0 - 95%5 - 95%
Storage relative humidity (H-H)Differs0 - 95%5 - 95%
Weight & dimensions4 differ
WidthDiffers737 mm56 mm
DepthDiffers864 mm44 mm
HeightDiffers2159 mm1245 mm
WeightDiffers584.1 kg3.07 kg
Packaging data4 differ
Package weightDiffers629.5 kg3.98 kg
Package widthDiffers914 mm387 mm
Package depthDiffers1219 mm323 mm
Package heightDiffers2261 mm2134 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.