Product comparison · 2 power distribution units (pdus)

APC InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless vs APC Rack PDU Extender, Basic, 2U, 32A, 230V, (4) IEC 309-32

Add a product
  • 16specifications compared
  • 13differ
  • 3identical
  • 12known for one product only

Key differences

  • Nominal input voltage
    • InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless:400 V
    • Rack PDU Extender, Basic, 2U, 32A, 230V, (4) IEC 309-32:230 V
  • Maximum input current per phase
    • InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless:173 A
    • Rack PDU Extender, Basic, 2U, 32A, 230V, (4) IEC 309-32:32 A
  • Operating temperature (T-T)
    • InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless:0 - 40 °C
    • Rack PDU Extender, Basic, 2U, 32A, 230V, (4) IEC 309-32:0 - 45 °C
  • Storage temperature (T-T)
    • InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless:-15 - 45 °C
    • Rack PDU Extender, Basic, 2U, 32A, 230V, (4) IEC 309-32:-25 - 65 °C
  • Operating relative humidity (H-H)
    • InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless:0 - 95%
    • Rack PDU Extender, Basic, 2U, 32A, 230V, (4) IEC 309-32:0 - 45%
  • Width
    • InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless:737 mm
    • Rack PDU Extender, Basic, 2U, 32A, 230V, (4) IEC 309-32:437 mm
  • Depth
    • InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless:864 mm
    • Rack PDU Extender, Basic, 2U, 32A, 230V, (4) IEC 309-32:89 mm
  • Height
    • InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless:2159 mm
    • Rack PDU Extender, Basic, 2U, 32A, 230V, (4) IEC 309-32:89 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of InfraStruXure PDU 80kW 400V/400V W/ MBP Xmerless, Rack PDU Extender, Basic, 2U, 32A, 230V, (4) IEC 309-32
28 specifications
Designidentical
PDU typesKnown for oneUnknown — not stated by the sourceBasic
Rack capacityKnown for oneUnknown — not stated by the source2U
MountingKnown for oneUnknown — not stated by the sourceHorizontal
Product colourBlackBlack
Ports & interfacesidentical
AC outlets quantityKnown for oneUnknown — not stated by the source4 AC outlet(s)
Input connection typeKnown for oneUnknown — not stated by the sourceHard Wire 3-wire
Output connectionsKnown for oneUnknown — not stated by the source(4) IEC 309
I/O portsKnown for oneUnknown — not stated by the sourceHard Wire 3-wire (4) IEC 309
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source8.53 m
Power2 differ
Nominal input voltageDiffers400 V230 V
Nominal output voltageKnown for oneUnknown — not stated by the source230 V
Output voltage230 V230 V
Load capacityKnown for oneUnknown — not stated by the source7680 VA
Maximum input current per phaseDiffers173 A32 A
Maximum total current draw per phaseKnown for oneUnknown — not stated by the source32 A
Maximum powerKnown for oneUnknown — not stated by the source7680 W
Operational conditions3 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 45 °C
Storage temperature (T-T)Differs-15 - 45 °C-25 - 65 °C
Operating relative humidity (H-H)Differs0 - 95%0 - 45%
Storage relative humidity (H-H)0 - 95%0 - 95%
Weight & dimensions4 differ
WidthDiffers737 mm437 mm
DepthDiffers864 mm89 mm
HeightDiffers2159 mm89 mm
WeightDiffers584.1 kg4.09 kg
Packaging data4 differ
Package weightDiffers629.5 kg5 kg
Package widthDiffers914 mm521 mm
Package depthDiffers1219 mm521 mm
Package heightDiffers2261 mm152 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.