Product comparison · 2 power distribution units (pdus)

APC InfraStruXure® PDU 40kW 208V/208V W/ MBP vs APC Rack PDU,Metered,ZeroU,5.7kW

Add a product
  • 14specifications compared
  • 13differ
  • 1identical
  • 4known for one product only

Key differences

The APC InfraStruXure® PDU 40kW 208V/208V W/ MBP has 139 A more maximum input current per phase than the APC Rack PDU,Metered,ZeroU,5.7kW (155 A vs 16 A). The APC InfraStruXure® PDU 40kW 208V/208V W/ MBP has 123 A more maximum total current draw per phase than the APC Rack PDU,Metered,ZeroU,5.7kW (139 A vs 16 A). The APC Rack PDU,Metered,ZeroU,5.7kW has 5 - 95% more operating relative humidity (H-H) than the APC InfraStruXure® PDU 40kW 208V/208V W/ MBP (5 - 95% vs 0 - 95%). Product colour: Black on the APC InfraStruXure® PDU 40kW 208V/208V W/ MBP, Beige on the APC Rack PDU,Metered,ZeroU,5.7kW. Output connections: -(1) NEMA L21-20. -(1) NEMA L6-30R. on the APC InfraStruXure® PDU 40kW 208V/208V W/ MBP, -(21) NEMA 5-20R. -(6) NEMA L6-20R. on the APC Rack PDU,Metered,ZeroU,5.7kW.

  • Product colour
    • InfraStruXure® PDU 40kW 208V/208V W/ MBP:Black
    • Rack PDU,Metered,ZeroU,5.7kW:Beige
  • Maximum input current per phase
    • InfraStruXure® PDU 40kW 208V/208V W/ MBP:155 A
    • Rack PDU,Metered,ZeroU,5.7kW:16 A
  • Maximum total current draw per phase
    • InfraStruXure® PDU 40kW 208V/208V W/ MBP:139 A
    • Rack PDU,Metered,ZeroU,5.7kW:16 A
  • Certification
    • InfraStruXure® PDU 40kW 208V/208V W/ MBP:cUL,UL 60950.
    • Rack PDU,Metered,ZeroU,5.7kW:cUL,FCC 15 A,UL,VCCI
  • Operating temperature (T-T)
    • InfraStruXure® PDU 40kW 208V/208V W/ MBP:0 - 40 °C
    • Rack PDU,Metered,ZeroU,5.7kW:-5 - 45 °C
  • Storage temperature (T-T)
    • InfraStruXure® PDU 40kW 208V/208V W/ MBP:0 - 45 °C
    • Rack PDU,Metered,ZeroU,5.7kW:-25 - 65 °C
  • Operating relative humidity (H-H)
    • InfraStruXure® PDU 40kW 208V/208V W/ MBP:0 - 95%
    • Rack PDU,Metered,ZeroU,5.7kW:5 - 95%
  • Storage relative humidity (H-H)
    • InfraStruXure® PDU 40kW 208V/208V W/ MBP:0 - 95%
    • Rack PDU,Metered,ZeroU,5.7kW:5 - 95%

Side by side

Differences highlightedShow differences only (off)
Comparison of InfraStruXure® PDU 40kW 208V/208V W/ MBP, Rack PDU,Metered,ZeroU,5.7kW
18 specifications
Design1 differ
Product colourDiffersBlackBeige
Ports & interfaces1 differ
Input connection typeKnown for oneUnknown — not stated by the sourceNEMA L21-20P
Output connectionsDiffers-(1) NEMA L21-20. -(1) NEMA L6-30R.-(21) NEMA 5-20R. -(6) NEMA L6-20R.
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source2.44 m
Power2 differ
Nominal input voltage208 V208 V
Load capacityKnown for oneUnknown — not stated by the source5700 VA
Maximum input current per phaseDiffers155 A16 A
Maximum total current draw per phaseDiffers139 A16 A
AC input frequencyKnown for one60 HzUnknown — not stated by the source
Certificates1 differ
CertificationDifferscUL,UL 60950.cUL,FCC 15 A,UL,VCCI
Operational conditions4 differ
Operating temperature (T-T)Differs0 - 40 °C-5 - 45 °C
Storage temperature (T-T)Differs0 - 45 °C-25 - 65 °C
Operating relative humidity (H-H)Differs0 - 95%5 - 95%
Storage relative humidity (H-H)Differs0 - 95%5 - 95%
Weight & dimensions4 differ
WidthDiffers610 mm89 mm
DepthDiffers914 mm44 mm
HeightDiffers2057 mm1524 mm
WeightDiffers580 kg8.18 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons