Product comparison · 2 power distribution units (pdus)

APC APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black vs APC NetShelter Rack PDU Advanced Gen 2, Switched, 11.5kW, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet

Add a product
  • 20specifications compared
  • 10differ
  • 10identical
  • 24known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Gen 2, Switched, 11.5kW, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet has 10 A more maximum current than the APC APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black (60 A vs 50 A). The APC NetShelter Rack PDU Advanced Gen 2, Switched, 11.5kW, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet has 192 V more nominal output voltage than the APC APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black (400 V vs 208 V). The APC NetShelter Rack PDU Advanced Gen 2, Switched, 11.5kW, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet has 32 V more output voltage than the APC APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black (240 V vs 208 V). Nominal input voltage: 200 - 240 V on the APC APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black, 415 3 phases; 400 3 phases on the APC NetShelter Rack PDU Advanced Gen 2, Switched, 11.5kW, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet.

  • Nominal input voltage
    • APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:200 - 240 V
    • NetShelter Rack PDU Advanced Gen 2, Switched, 11.5kW, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:415 3 phases; 400 3 phases
  • Maximum current
    • APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:50 A
    • NetShelter Rack PDU Advanced Gen 2, Switched, 11.5kW, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:60 A
  • Nominal output voltage
    • APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:208 V
    • NetShelter Rack PDU Advanced Gen 2, Switched, 11.5kW, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:400 V
  • Output voltage
    • APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:208 V
    • NetShelter Rack PDU Advanced Gen 2, Switched, 11.5kW, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:240 V
  • Load capacity
    • APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:14400 VA
    • NetShelter Rack PDU Advanced Gen 2, Switched, 11.5kW, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:34600 VA
  • Height
    • APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:1780 mm
    • NetShelter Rack PDU Advanced Gen 2, Switched, 11.5kW, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:1490 mm
  • Weight
    • APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:10.6 kg
    • NetShelter Rack PDU Advanced Gen 2, Switched, 11.5kW, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:7.2 kg
  • Package weight
    • APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:13.6 kg
    • NetShelter Rack PDU Advanced Gen 2, Switched, 11.5kW, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:17 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of APDU11451ME, NetShelter Rack PDU Advanced Gen 2, Switched, 11.5kW, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet
44 specifications
Designidentical
TypeKnown for oneUnknown — not stated by the sourceThree-phase
MountingKnown for oneVerticalUnknown — not stated by the source
Ports & interfaces1 differ
AC outlet typesDiffersC13 coupler, C19 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source5
USB ports quantityKnown for oneUnknown — not stated by the source1
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 60309 20 A 3P + N + PE
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3
Power5 differ
Nominal input voltageDiffers200 - 240 V415 3 phases; 400 3 phases
Maximum currentDiffers50 A60 A
Nominal output voltageDiffers208 V400 V
Output voltageDiffers208 V240 V
Load capacityDiffers14400 VA34600 VA
Number of phasesKnown for oneUnknown — not stated by the source3
Battery replacement accessibilityKnown for oneUnknown — not stated by the sourceNon-removable
Maximum powerKnown for one14400 WUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneUnknown — not stated by the sourceYes
CertificationKnown for oneUnknown — not stated by the sourceUKCA
Weight & dimensions2 differ
HeightDiffers1780 mm1490 mm
WeightDiffers10.6 kg7.2 kg
Packaging data2 differ
Package weightDiffers13.6 kg17 kg
Package heightDiffers1980 mm2110 mm
Technical detailsidentical
Preferred mounting positionKnown for oneUnknown — not stated by the sourceno preference
Removable batteryKnown for oneUnknown — not stated by the sourceNo
Packaging without single use plasticKnown for oneUnknown — not stated by the sourceNo
SCIP numberKnown for oneUnknown — not stated by the source31346aed-552c-4a16-81d9-e683a383b6da
Sustainable packagingKnown for oneUnknown — not stated by the sourceNo
Take-back systemKnown for oneUnknown — not stated by the sourceNo
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceUnited States
Customs product code (TARIC)Known for oneUnknown — not stated by the source8537109899
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °FUnknown — not stated by the source
Operating temperature (charge) (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.