Product comparison · 2 power distribution units (pdus)

APC AP8868 power distribution unit (PDU) 42 AC outlet(s) 0U Black vs APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW

Add a product
  • 30specifications compared
  • 9differ
  • 21identical
  • 8known for one product only

Key differences

  • Nominal input voltage
    • AP8868 power distribution unit (PDU) 42 AC outlet(s) 0U Black:208 V
    • NetShelter Metered Rack PDU, 0U, 3PH, 22kW:400 V
  • Nominal output voltage
    • AP8868 power distribution unit (PDU) 42 AC outlet(s) 0U Black:208 V
    • NetShelter Metered Rack PDU, 0U, 3PH, 22kW:230 V
  • Load capacity
    • AP8868 power distribution unit (PDU) 42 AC outlet(s) 0U Black:10000 VA
    • NetShelter Metered Rack PDU, 0U, 3PH, 22kW:22080 VA
  • Maximum input current per phase
    • AP8868 power distribution unit (PDU) 42 AC outlet(s) 0U Black:35 A
    • NetShelter Metered Rack PDU, 0U, 3PH, 22kW:32 A
  • Weight
    • AP8868 power distribution unit (PDU) 42 AC outlet(s) 0U Black:8.52 kg
    • NetShelter Metered Rack PDU, 0U, 3PH, 22kW:8.72 kg
  • Package weight
    • AP8868 power distribution unit (PDU) 42 AC outlet(s) 0U Black:11.4 kg
    • NetShelter Metered Rack PDU, 0U, 3PH, 22kW:11.6 kg
  • Total carbon footprint (kg of CO2e)
    • AP8868 power distribution unit (PDU) 42 AC outlet(s) 0U Black:51678.25
    • NetShelter Metered Rack PDU, 0U, 3PH, 22kW:57837.86

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8868, AP8886
38 specifications
Designidentical
PDU typesMeteredMetered
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces1 differ
AC outlets quantity42 AC outlet(s)42 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC309
AC outlet typesKnown for oneUnknown — not stated by the sourceC13 coupler, C19 coupler
Output connectionsDiffers36 x IEC 320 C13 6 x IEC 320 C1930 x IEC 320 C13 12 x IEC 320 C19
Input connection typeKnown for oneCS8365Unknown — not stated by the source
Featuresidentical
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Cable length1.83 m1.83 m
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Power4 differ
Nominal input voltageDiffers208 V400 V
AC input frequency50 - 60 Hz50 - 60 Hz
Maximum currentKnown for oneUnknown — not stated by the source32 A
Nominal output voltageDiffers208 V230 V
Load capacityDiffers10000 VA22080 VA
Maximum input current per phaseDiffers35 A32 A
Maximum powerKnown for oneUnknown — not stated by the source22000 W
Power protection featuresOverloadOverload
Maximum total current draw per phaseKnown for one35 AUnknown — not stated by the source
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDifferscUL, EN 55022, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC, ICES-003, UL, VCCIEN 55022 A,EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, VCCI A, VDE REACH: No SVHCs
Operational conditionsidentical
Operating temperature (T-T)0 - 55 °C0 - 55 °C
Storage temperature (T-T)-25 - 65 °C-25 - 65 °C
Operating relative humidity (H-H)5 - 95%5 - 95%
Storage relative humidity (H-H)5 - 95%5 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Weight & dimensions1 differ
Width56 mm56 mm
Depth51 mm51 mm
Height1829 mm1829 mm
WeightDiffers8.52 kg8.72 kg
Packaging data1 differ
Package weightDiffers11.4 kg11.6 kg
Package width170 mm170 mm
Package depth112 mm112 mm
Package height2050 mm2050 mm
Logistics data1 differ
Total carbon footprint (kg of CO2e)Differs51678.2557837.86

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.