Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU, Metered, 0U, 5.0kW vs ATEN 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software

Add a product
  • 25specifications compared
  • 24differ
  • 1identical
  • 33known for one product only

Key differences

The ATEN 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software has 1 U more rack capacity than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (1U vs 0U). The ATEN 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software has 0.1 m more cable length than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (3 m vs 2.9 m). The APC NetShelter Rack PDU, Metered, 0U, 5.0kW has 14 A more maximum current than the ATEN 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software (30 A vs 16 A). PDU types: Basic on the APC NetShelter Rack PDU, Metered, 0U, 5.0kW, Metered, Switched on the ATEN 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software. Mounting: Vertical on the APC NetShelter Rack PDU, Metered, 0U, 5.0kW, Horizontal on the ATEN 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software.

  • PDU types
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:Basic
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:Metered, Switched
  • Rack capacity
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:0U
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:1U
  • Mounting
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:Vertical
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:Horizontal
  • AC outlets quantity
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:42 AC outlet(s)
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:8 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:NEMA L6-30P
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:C20 coupler
  • AC outlet types
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:NEMA L6-30P
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:C13 coupler, C19 coupler
  • Cable length
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:2.9 m
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:3 m
  • Nominal input voltage
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:200; 208 V
    • 1U 16A 8 Outlet Switched + Metered PDU + Free Eco PDU Manager Software:100 - 240 V

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8841, PE8208G-ATB-G
58 specifications
Design3 differ
PDU typesDiffersBasicMetered, Switched
TypeKnown for oneSingle-phaseUnknown — not stated by the source
Rack capacityDiffers0U1U
MountingDiffersVerticalHorizontal
Product colourBlackBlack
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers42 AC outlet(s)8 AC outlet(s)
Power plugDiffersNEMA L6-30PC20 coupler
AC outlet typesDiffersNEMA L6-30PC13 coupler, C19 coupler
Input connection typeKnown for oneNEMA L6-30PUnknown — not stated by the source
Output connectionsKnown for one36x IEC 320 C13 6x IEC 320 C19Unknown — not stated by the source
Features1 differ
Cable lengthDiffers2.9 m3 m
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Power4 differ
Nominal input voltageDiffers200; 208 V100 - 240 V
AC input frequencyDiffers50-60 Hz50 - 60 Hz
Maximum currentDiffers30 A16 A
Output voltageKnown for one200 V; 208 VUnknown — not stated by the source
Load capacityDiffers4992 VA3680 VA
Maximum input current per phaseKnown for one30 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one30 AUnknown — not stated by the source
Nominal output voltageKnown for oneUnknown — not stated by the source100 - 240 V
Maximum powerKnown for oneUnknown — not stated by the source100 W
Certificates1 differ
Compliance certificatesKnown for oneRoHS, REACH, WEEEUnknown — not stated by the source
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationDiffersCSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS,REACHCE TUV-CB CE-LVD GOST
Operational conditions3 differ
Operating temperature (T-T)Differs-5 - 60 °C0 - 50 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%0 - 80%
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm220.4 mm
DepthDiffers44 mm432.4 mm
HeightDiffers1791 mm44 mm
WeightDiffers6.84 kg3.38 kg
Packaging content1 differ
Cables includedDiffersSerialAC
ManualKnown for oneYesUnknown — not stated by the source
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Packaging data4 differ
Package weightDiffers6.47 kg4.04 kg
Package widthDiffers107 mm116 mm
Package depthDiffers162 mm499 mm
Package heightDiffers2000 mm324 mm
Technical detailsidentical
Halogen freeKnown for oneNoUnknown — not stated by the source
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Removable batteryKnown for oneYesUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneIndiaUnknown — not stated by the source
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Total carbon footprint (kg of CO2e)Known for one2676.8173692539Unknown — not stated by the source
Master (outer) case net weightKnown for oneUnknown — not stated by the source10.1 kg
Master (outer) case widthKnown for oneUnknown — not stated by the source388 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source519 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source348 mm
Master (outer) case gross weightKnown for oneUnknown — not stated by the source13.3 kg
Products per master (outer) caseKnown for oneUnknown — not stated by the source3 pc(s)