Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU, Metered, 0U, 5.0kW vs ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black

Add a product
  • 21specifications compared
  • 19differ
  • 2identical
  • 38known for one product only

Key differences

The ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black has 1 U more rack capacity than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (1U vs 0U). The ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black has 0.1 m more cable length than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (3 m vs 2.9 m). The APC NetShelter Rack PDU, Metered, 0U, 5.0kW has 18 A more maximum current than the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black (30 A vs 12 A). PDU types: Basic on the APC NetShelter Rack PDU, Metered, 0U, 5.0kW, Metered, Switched on the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black. AC outlets quantity: 42 AC outlet(s) on the APC NetShelter Rack PDU, Metered, 0U, 5.0kW, 8 AC outlet(s) on the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black.

  • PDU types
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:Basic
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:Metered, Switched
  • Rack capacity
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:0U
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:1U
  • AC outlets quantity
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:42 AC outlet(s)
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:8 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:NEMA L6-30P
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:NEMA 5-20P
  • AC outlet types
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:NEMA L6-30P
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:NEMA 5–20R
  • Cable length
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:2.9 m
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:3 m
  • Nominal input voltage
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:200; 208 V
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:100 - 240 V
  • AC input frequency
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:50-60 Hz
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:50/60 Hz

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8841, PE8208AV-ATB-G
59 specifications
Design2 differ
PDU typesDiffersBasicMetered, Switched
TypeKnown for oneSingle-phaseUnknown — not stated by the source
Rack capacityDiffers0U1U
MountingKnown for oneVerticalUnknown — not stated by the source
Product colourBlackBlack
Ports & interfaces3 differ
AC outlets quantityDiffers42 AC outlet(s)8 AC outlet(s)
Power plugDiffersNEMA L6-30PNEMA 5-20P
AC outlet typesDiffersNEMA L6-30PNEMA 5–20R
Input connection typeKnown for oneNEMA L6-30PUnknown — not stated by the source
Output connectionsKnown for one36x IEC 320 C13 6x IEC 320 C19Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
Features1 differ
Cable lengthDiffers2.9 m3 m
Security algorithmsKnown for oneUnknown — not stated by the source128-bit SSL
Password protectionKnown for oneUnknown — not stated by the sourceYes
Power4 differ
Nominal input voltageDiffers200; 208 V100 - 240 V
AC input frequencyDiffers50-60 Hz50/60 Hz
Maximum currentDiffers30 A12 A
Output voltageKnown for one200 V; 208 VUnknown — not stated by the source
Load capacityDiffers4992 VA2400 VA
Maximum input current per phaseKnown for one30 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one30 AUnknown — not stated by the source
Nominal output voltageKnown for oneUnknown — not stated by the source100 - 240 V
Maximum powerKnown for oneUnknown — not stated by the source1440 W
Circuit breakerKnown for oneUnknown — not stated by the sourceYes
Certificates1 differ
Compliance certificatesDiffersRoHS, REACH, WEEEFederal Communications Commission (FCC)
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationKnown for oneCSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS,REACHUnknown — not stated by the source
Operational conditions3 differ
Operating temperature (T-T)Differs-5 - 60 °C0 - 50 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%0 - 80%
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm220.4 mm
DepthDiffers44 mm432.4 mm
HeightDiffers1791 mm44 mm
WeightDiffers6.84 kg2.84 kg
Packaging content1 differ
Cables includedDiffersSerialAC
ManualYesYes
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Packaging dataidentical
Package weightKnown for one6.47 kgUnknown — not stated by the source
Package widthKnown for one107 mmUnknown — not stated by the source
Package depthKnown for one162 mmUnknown — not stated by the source
Package heightKnown for one2000 mmUnknown — not stated by the source
Technical detailsidentical
Halogen freeKnown for oneNoUnknown — not stated by the source
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Removable batteryKnown for oneYesUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneIndiaUnknown — not stated by the source
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Total carbon footprint (kg of CO2e)Known for one2676.8173692539Unknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Firmware upgradeableKnown for oneUnknown — not stated by the sourceYes
Management protocolsKnown for oneUnknown — not stated by the sourceSNMP Manager V3
Supported network protocolsKnown for oneUnknown — not stated by the sourceTCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Ping, Telnet
Sustainabilityidentical
Sustainability complianceKnown for oneUnknown — not stated by the sourceYes

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.