Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU, Metered, 0U, 5.0kW vs APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets

Add a product
  • 26specifications compared
  • 19differ
  • 7identical
  • 23known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 70 A more maximum current than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (100 A vs 30 A). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 23,808 VA more load capacity than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (28800 VA vs 4992 VA). The APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets has 31 mm more depth than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (75 mm vs 44 mm). PDU types: Basic on the APC NetShelter Rack PDU, Metered, 0U, 5.0kW, Metered on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets. Type: Single-phase on the APC NetShelter Rack PDU, Metered, 0U, 5.0kW, Three-phase on the APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets.

  • PDU types
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:Basic
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Metered
  • Type
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:Single-phase
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:Three-phase
  • AC outlets quantity
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:42 AC outlet(s)
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:30 AC outlet(s)
  • Power plug
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:NEMA L6-30P
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:IEC 60309
  • Nominal input voltage
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:200; 208 V
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V
  • AC input frequency
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:50-60 Hz
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:50/60 Hz
  • Maximum current
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:30 A
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:100 A
  • Output voltage
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:200 V; 208 V
    • NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets:208 V

Side by side

Differences highlightedShow differences only (on)
Comparison of AP8841, NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 208V, 28.8kVA 100A, 30 Outlets
49 specifications
Design2 differ
PDU typesDiffersBasicMetered
TypeDiffersSingle-phaseThree-phase
Ports & interfaces3 differ
AC outlets quantityDiffers42 AC outlet(s)30 AC outlet(s)
Power plugDiffersNEMA L6-30PIEC 60309
AC outlet typesDiffersNEMA L6-30PC15 coupler, C13 coupler, C19 coupler, C21 coupler
Input connection typeKnown for oneNEMA L6-30PUnknown — not stated by the source
Output connectionsKnown for one36x IEC 320 C13 6x IEC 320 C19Unknown — not stated by the source
Featuresidentical
Cable lengthKnown for one2.9 mUnknown — not stated by the source
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP67
Power5 differ
Nominal input voltageDiffers200; 208 V208 V
AC input frequencyDiffers50-60 Hz50/60 Hz
Maximum currentDiffers30 A100 A
Output voltageDiffers200 V; 208 V208 V
Load capacityDiffers4992 VA28800 VA
Maximum input current per phaseKnown for one30 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one30 AUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHS, REACH, WEEEUnknown — not stated by the source
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationKnown for oneCSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS,REACHUnknown — not stated by the source
Operational conditions2 differ
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%5 - 90%
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions3 differ
DepthDiffers44 mm75 mm
HeightDiffers1791 mm1900 mm
WeightDiffers6.84 kg14 kg
Packaging contentidentical
Cables includedKnown for oneSerialUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Packaging data4 differ
Package weightDiffers6.47 kg19.8 kg
Package widthDiffers107 mm350 mm
Package depthDiffers162 mm165 mm
Package heightDiffers2000 mm2110 mm
Technical detailsidentical
Halogen freeKnown for oneNoUnknown — not stated by the source
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Removable batteryKnown for oneYesUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneIndiaUnknown — not stated by the source
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Total carbon footprint (kg of CO2e)Known for one2676.8173692539Unknown — not stated by the source
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.