Product comparison · 2 power distribution units (pdus)

APC NetShelter Rack PDU, Metered, 0U, 5.0kW vs APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black

Add a product
  • 19specifications compared
  • 14differ
  • 5identical
  • 32known for one product only

Key differences

The APC NetShelter Rack PDU, Metered, 0U, 5.0kW has 6 A more maximum current than the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black (30 A vs 24 A). The APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black has 31 mm more depth than the APC NetShelter Rack PDU, Metered, 0U, 5.0kW (75 mm vs 44 mm). The APC NetShelter Rack PDU, Metered, 0U, 5.0kW has 301 mm more height than the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black (1791 mm vs 1490 mm). PDU types: Basic on the APC NetShelter Rack PDU, Metered, 0U, 5.0kW, Metered on the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black. AC outlets quantity: 42 AC outlet(s) on the APC NetShelter Rack PDU, Metered, 0U, 5.0kW, 40 AC outlet(s) on the APC NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black.

  • PDU types
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:Basic
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:Metered
  • AC outlets quantity
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:42 AC outlet(s)
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:40 AC outlet(s)
  • Nominal input voltage
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:200; 208 V
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:208 V
  • AC input frequency
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:50-60 Hz
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:50/60 Hz
  • Maximum current
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:30 A
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:24 A
  • Depth
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:44 mm
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:75 mm
  • Height
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:1791 mm
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:1490 mm
  • Weight
    • NetShelter Rack PDU, Metered, 0U, 5.0kW:6.84 kg
    • NetShelter power distribution unit (PDU) 40 AC outlet(s) 0U Black:6.2 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8841, NetShelter
51 specifications
Design1 differ
PDU typesDiffersBasicMetered
TypeSingle-phaseSingle-phase
Rack capacity0U0U
MountingKnown for oneVerticalUnknown — not stated by the source
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers42 AC outlet(s)40 AC outlet(s)
Power plugKnown for oneNEMA L6-30PUnknown — not stated by the source
AC outlet typesDiffersNEMA L6-30PC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeKnown for oneNEMA L6-30PUnknown — not stated by the source
Output connectionsKnown for one36x IEC 320 C13 6x IEC 320 C19Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source5
Featuresidentical
Cable lengthKnown for one2.9 mUnknown — not stated by the source
Power3 differ
Nominal input voltageDiffers200; 208 V208 V
AC input frequencyDiffers50-60 Hz50/60 Hz
Maximum currentDiffers30 A24 A
Output voltageKnown for one200 V; 208 VUnknown — not stated by the source
Load capacity4992 VA4992 VA
Maximum input current per phaseKnown for one30 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one30 AUnknown — not stated by the source
Nominal output voltageKnown for oneUnknown — not stated by the source208 V
Number of phasesKnown for oneUnknown — not stated by the source1
Certificates1 differ
Compliance certificatesKnown for oneRoHS, REACH, WEEEUnknown — not stated by the source
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationDiffersCSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS,REACHUKCA, CE, EN 62368-1, RoHS
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 60 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions3 differ
Width56 mm56 mm
DepthDiffers44 mm75 mm
HeightDiffers1791 mm1490 mm
WeightDiffers6.84 kg6.2 kg
Packaging contentidentical
Cables includedKnown for oneSerialUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Packaging data4 differ
Package weightDiffers6.47 kg8.2 kg
Package widthDiffers107 mm116 mm
Package depthDiffers162 mm208 mm
Package heightDiffers2000 mm1720 mm
Technical detailsidentical
Halogen freeKnown for oneNoUnknown — not stated by the source
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Removable batteryKnown for oneYesUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneIndiaUnknown — not stated by the source
Customs product code (TARIC)Known for one8537109899Unknown — not stated by the source
Total carbon footprint (kg of CO2e)Known for one2676.8173692539Unknown — not stated by the source
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons