Product comparison · 2 power distribution units (pdus)

APC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 11.0kW, 230V, (21) C13 & (3) C19 vs CyberPower CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black

Add a product
  • 20specifications compared
  • 16differ
  • 4identical
  • 15known for one product only

Key differences

  • Rack capacity
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 11.0kW, 230V, (21) C13 & (3) C19:0U
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:1U
  • AC outlets quantity
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 11.0kW, 230V, (21) C13 & (3) C19:24 AC outlet(s)
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:10 AC outlet(s)
  • AC outlet types
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 11.0kW, 230V, (21) C13 & (3) C19:C13 coupler, C19 coupler
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:NEMA 5–15R
  • Cable length
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 11.0kW, 230V, (21) C13 & (3) C19:1.83 m
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:4.57 m
  • Nominal input voltage
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 11.0kW, 230V, (21) C13 & (3) C19:400 V
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:120 V
  • AC input frequency
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 11.0kW, 230V, (21) C13 & (3) C19:50 - 60 Hz
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:60 Hz
  • Maximum current
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 11.0kW, 230V, (21) C13 & (3) C19:16 A
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:15 A
  • Load capacity
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 11.0kW, 230V, (21) C13 & (3) C19:11040 VA
    • CPS-1215RM power distribution unit (PDU) 10 AC outlet(s) 1U Black:1800 VA

Side by side

Differences highlightedShow differences only (on)
Comparison of AP8681, CPS-1215RM
35 specifications
Design2 differ
PDU typesDiffersMetered, Metered-by-outlet, SwitchedBasic
Rack capacityDiffers0U1U
MountingKnown for oneVerticalUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers24 AC outlet(s)10 AC outlet(s)
AC outlet typesDiffersC13 coupler, C19 couplerNEMA 5–15R
Power plugKnown for oneUnknown — not stated by the sourceNEMA 5–15P
Features1 differ
Cable lengthDiffers1.83 m4.57 m
Management featuresidentical
MonitoringKnown for oneCurrent, Power, VoltageUnknown — not stated by the source
Outlet controlKnown for oneLock-out, Recycle, Turn off, Turn onUnknown — not stated by the source
Power4 differ
Nominal input voltageDiffers400 V120 V
AC input frequencyDiffers50 - 60 Hz60 Hz
Maximum currentDiffers16 A15 A
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Load capacityDiffers11040 VA1800 VA
Maximum input current per phaseKnown for one16 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one16 AUnknown — not stated by the source
Maximum powerKnown for one11040 WUnknown — not stated by the source
Certificates1 differ
CertificationDiffersEN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, UL, VDEUL
Operational conditions2 differ
Operating temperature (T-T)Differs-5 - 45 °C-20 - 46 °C
Operating relative humidity (H-H)Differs5 - 95%0 - 95%
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage temperature (T-T)Known for oneUnknown — not stated by the source-15 - 45 °C
Weight & dimensions4 differ
WidthDiffers56 mm438.1 mm
DepthDiffers51 mm120.7 mm
HeightDiffers1829 mm44.5 mm
WeightDiffers8.23 kg2.27 kg
Packaging dataidentical
Package weightKnown for one10.5 kgUnknown — not stated by the source
Package widthKnown for one162 mmUnknown — not stated by the source
Package depthKnown for one117 mmUnknown — not stated by the source
Package heightKnown for one2038 mmUnknown — not stated by the source
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one10364.02Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.