Product comparison · 2 power distribution units (pdus)

APC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19 vs CyberPower CPS-1220RM power distribution unit (PDU) 12 AC outlet(s) 1U Black

Add a product
  • 21specifications compared
  • 17differ
  • 4identical
  • 15known for one product only

Key differences

  • Rack capacity
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19:0U
    • CPS-1220RM power distribution unit (PDU) 12 AC outlet(s) 1U Black:1U
  • AC outlets quantity
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19:24 AC outlet(s)
    • CPS-1220RM power distribution unit (PDU) 12 AC outlet(s) 1U Black:12 AC outlet(s)
  • AC outlet types
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19:C13 coupler, C19 coupler
    • CPS-1220RM power distribution unit (PDU) 12 AC outlet(s) 1U Black:NEMA 5–20R
  • Nominal input voltage
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19:200-230 V
    • CPS-1220RM power distribution unit (PDU) 12 AC outlet(s) 1U Black:120 V
  • AC input frequency
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19:50 - 60 Hz
    • CPS-1220RM power distribution unit (PDU) 12 AC outlet(s) 1U Black:60 Hz
  • Maximum current
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19:16 A
    • CPS-1220RM power distribution unit (PDU) 12 AC outlet(s) 1U Black:20 A
  • Nominal output voltage
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19:200-230 V
    • CPS-1220RM power distribution unit (PDU) 12 AC outlet(s) 1U Black:400 V
  • Load capacity
    • Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19:3680 VA
    • CPS-1220RM power distribution unit (PDU) 12 AC outlet(s) 1U Black:2400 VA

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8659, CPS-1220RM
36 specifications
Design2 differ
PDU typesDiffersMetered, Metered-by-outlet, SwitchedBasic
Rack capacityDiffers0U1U
MountingKnown for oneVerticalUnknown — not stated by the source
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers24 AC outlet(s)12 AC outlet(s)
AC outlet typesDiffersC13 coupler, C19 couplerNEMA 5–20R
Power plugKnown for oneUnknown — not stated by the sourceNEMA 5–20P
Management featuresidentical
MonitoringKnown for oneCurrent, Power, VoltageUnknown — not stated by the source
Outlet controlKnown for oneLock-out, Recycle, Turn off, Turn onUnknown — not stated by the source
Power5 differ
Nominal input voltageDiffers200-230 V120 V
AC input frequencyDiffers50 - 60 Hz60 Hz
Maximum currentDiffers16 A20 A
Nominal output voltageDiffers200-230 V400 V
Load capacityDiffers3680 VA2400 VA
Maximum input current per phaseKnown for one16 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one16 AUnknown — not stated by the source
Maximum powerKnown for one3680 WUnknown — not stated by the source
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDiffersEN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, PSE, UL, VCCI A, VDEUL ETL
Operational conditions3 differ
Operating temperature (T-T)Differs-5 - 45 °C0 - 35 °C
Storage temperature (T-T)Differs-25 - 65 °C-15 - 45 °C
Operating relative humidity (H-H)Differs5 - 95%0 - 95%
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Weight & dimensions4 differ
WidthDiffers56 mm438.1 mm
DepthDiffers51 mm120.7 mm
HeightDiffers1829 mm44.5 mm
WeightDiffers6.09 kg2.72 kg
Packaging dataidentical
Package weightKnown for one8.36 kgUnknown — not stated by the source
Package widthKnown for one162 mmUnknown — not stated by the source
Package depthKnown for one117 mmUnknown — not stated by the source
Package heightKnown for one2038 mmUnknown — not stated by the source
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one537.26Unknown — not stated by the source
Featuresidentical
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source4.5 m

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.