Product comparison · 2 power distribution units (pdus)

APC AP7802B power distribution unit (PDU) 16 AC outlet(s) 2U Black vs APC Rack PDU, Switched, 1U, 20A

Add a product
  • 29specifications compared
  • 20differ
  • 9identical
  • 6known for one product only

Key differences

  • PDU types
    • AP7802B power distribution unit (PDU) 16 AC outlet(s) 2U Black:Metered
    • Rack PDU, Switched, 1U, 20A:Switched
  • Rack capacity
    • AP7802B power distribution unit (PDU) 16 AC outlet(s) 2U Black:2U
    • Rack PDU, Switched, 1U, 20A:1U
  • AC outlets quantity
    • AP7802B power distribution unit (PDU) 16 AC outlet(s) 2U Black:16 AC outlet(s)
    • Rack PDU, Switched, 1U, 20A:8 AC outlet(s)
  • Input connection type
    • AP7802B power distribution unit (PDU) 16 AC outlet(s) 2U Black:NEMA L5-30P
    • Rack PDU, Switched, 1U, 20A:NEMA L5-20P
  • Nominal input voltage
    • AP7802B power distribution unit (PDU) 16 AC outlet(s) 2U Black:100 - 120 V
    • Rack PDU, Switched, 1U, 20A:120 V
  • Maximum current
    • AP7802B power distribution unit (PDU) 16 AC outlet(s) 2U Black:30 A
    • Rack PDU, Switched, 1U, 20A:20 A
  • Load capacity
    • AP7802B power distribution unit (PDU) 16 AC outlet(s) 2U Black:2880 VA
    • Rack PDU, Switched, 1U, 20A:2400 VA
  • Maximum total current draw per phase
    • AP7802B power distribution unit (PDU) 16 AC outlet(s) 2U Black:24 A
    • Rack PDU, Switched, 1U, 20A:16 A

Side by side

Differences highlightedShow differences only (off)
Comparison of AP7802B, AP7901B
35 specifications
Design2 differ
PDU typesDiffersMeteredSwitched
Rack capacityDiffers2U1U
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers16 AC outlet(s)8 AC outlet(s)
AC outlet typesNEMA 5–20RNEMA 5–20R
Input connection typeDiffersNEMA L5-30PNEMA L5-20P
Featuresidentical
LED indicatorsKnown for oneAlarmUnknown — not stated by the source
Cable length3.66 m3.66 m
Management featuresidentical
MonitoringCurrentCurrent
Outlet controlKnown for oneUnknown — not stated by the sourceRecycle, Turn off
Power4 differ
Nominal input voltageDiffers100 - 120 V120 V
AC input frequency50 - 60 Hz50 - 60 Hz
Maximum currentDiffers30 A20 A
Nominal output voltage120 V120 V
Load capacityDiffers2880 VA2400 VA
Maximum total current draw per phaseDiffers24 A16 A
Maximum powerKnown for one14400 WUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Maximum input current per phaseKnown for oneUnknown — not stated by the source20 A
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDifferscUL Listed, CSA, FCC Part 15 Class A, ICES-003, UL 60950, UL ListedcUL, CSA, FCC 15 A, ICES-003, UL 60950, UL
Operational conditions3 differ
Operating temperature (T-T)Differs-5 - 45 °C0 - 45 °C
Storage temperature (T-T)-25 - 65 °C-25 - 65 °C
Operating relative humidity (H-H)Differs5 - 95%0 - 95%
Storage relative humidity (H-H)Differs5 - 95%0 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15000 m
Weight & dimensions4 differ
WidthDiffers444 mm445 mm
DepthDiffers112 mm108 mm
HeightDiffers88 mm44 mm
WeightDiffers3.36 kg2.27 kg
Packaging data4 differ
Package weightDiffers4.44 kg3.45 kg
Package widthDiffers508 mm470 mm
Package depthDiffers368 mm343 mm
Package heightDiffers140 mm70 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.