Product comparison · 2 power distribution units (pdus)

APC AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black vs Vertiv Knürr 03.630.805.1 power distribution unit (PDU) 5 AC outlet(s) 1U Black

Add a product
  • 11specifications compared
  • 9differ
  • 2identical
  • 26known for one product only

Key differences

The Vertiv Knürr 03.630.805.1 power distribution unit (PDU) 5 AC outlet(s) 1U Black has 12 A more maximum current than the APC AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black (32 A vs 20 A). The Vertiv Knürr 03.630.805.1 power distribution unit (PDU) 5 AC outlet(s) 1U Black has 28 mm more width than the APC AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black (84 mm vs 56 mm). The Vertiv Knürr 03.630.805.1 power distribution unit (PDU) 5 AC outlet(s) 1U Black has 328 mm more depth than the APC AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black (375 mm vs 47 mm). Rack capacity: 0U/2U on the APC AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black, 1U on the Vertiv Knürr 03.630.805.1 power distribution unit (PDU) 5 AC outlet(s) 1U Black. AC outlets quantity: 14 AC outlet(s) on the APC AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black, 5 AC outlet(s) on the Vertiv Knürr 03.630.805.1 power distribution unit (PDU) 5 AC outlet(s) 1U Black.

  • Rack capacity
    • AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black:0U/2U
    • Knürr 03.630.805.1 power distribution unit (PDU) 5 AC outlet(s) 1U Black:1U
  • AC outlets quantity
    • AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black:14 AC outlet(s)
    • Knürr 03.630.805.1 power distribution unit (PDU) 5 AC outlet(s) 1U Black:5 AC outlet(s)
  • Power plug
    • AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black:C20 coupler
    • Knürr 03.630.805.1 power distribution unit (PDU) 5 AC outlet(s) 1U Black:IEC 60309
  • AC outlet types
    • AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black:C13 coupler
    • Knürr 03.630.805.1 power distribution unit (PDU) 5 AC outlet(s) 1U Black:C13 coupler, C19 coupler
  • Maximum current
    • AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black:20 A
    • Knürr 03.630.805.1 power distribution unit (PDU) 5 AC outlet(s) 1U Black:32 A
  • Width
    • AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black:56 mm
    • Knürr 03.630.805.1 power distribution unit (PDU) 5 AC outlet(s) 1U Black:84 mm
  • Depth
    • AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black:47 mm
    • Knürr 03.630.805.1 power distribution unit (PDU) 5 AC outlet(s) 1U Black:375 mm
  • Height
    • AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black:523 mm
    • Knürr 03.630.805.1 power distribution unit (PDU) 5 AC outlet(s) 1U Black:60 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of AP6003A, 03.630.805.1
37 specifications
Design1 differ
PDU typesKnown for oneBasicUnknown — not stated by the source
TypeKnown for oneSingle-phaseUnknown — not stated by the source
Rack capacityDiffers0U/2U1U
MountingKnown for oneHorizontal/VerticalUnknown — not stated by the source
Product colourBlackBlack
Housing materialKnown for oneUnknown — not stated by the sourceSteel, Zinc
Ports & interfaces3 differ
AC outlets quantityDiffers14 AC outlet(s)5 AC outlet(s)
Power plugDiffersC20 couplerIEC 60309
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Input connection typeKnown for oneIEC-320 C20Unknown — not stated by the source
Power1 differ
Nominal input voltage230 V230 V
AC input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Maximum currentDiffers20 A32 A
Nominal output voltageKnown for one100-240 VUnknown — not stated by the source
Load capacityKnown for one3680 VAUnknown — not stated by the source
Maximum input current per phaseKnown for one16 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one16 AUnknown — not stated by the source
Maximum powerKnown for one3680 WUnknown — not stated by the source
Certificates1 differ
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationDifferscUL, UL, REACH- CE Label in accordance with low voltage directive 2006/95/EEC EMC Directive 2006/108/EEC - Innova GS - CSA NRTL/C
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 50 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers56 mm84 mm
DepthDiffers47 mm375 mm
HeightDiffers523 mm60 mm
WeightKnown for one1.88 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one2.55 kgUnknown — not stated by the source
Package widthKnown for one123 mmUnknown — not stated by the source
Package depthKnown for one107 mmUnknown — not stated by the source
Package heightKnown for one612 mmUnknown — not stated by the source
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source4 m
Cable typeKnown for oneUnknown — not stated by the sourceH05VV-F 5 G 4 mm2
Packaging contentidentical
Packaging contentKnown for oneUnknown — not stated by the source1 socket strip (PDU) 2 mounting brackets 1 19” mounting bracket (additional with 19 installation option) Operating instructions

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.