Product comparison · 2 power distribution units (pdus)

APC AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black vs Vertiv Knürr DIS Rack PDU, Compact, 0U, input GST18

Add a product
  • 13specifications compared
  • 13differ
  • 0identical
  • 23known for one product only

Key differences

The APC AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black has 4 A more maximum current than the Vertiv Knürr DIS Rack PDU, Compact, 0U, input GST18 (20 A vs 16 A). The APC AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black has 11.6 mm more width than the Vertiv Knürr DIS Rack PDU, Compact, 0U, input GST18 (56 mm vs 44.4 mm). The Vertiv Knürr DIS Rack PDU, Compact, 0U, input GST18 has 536 mm more depth than the APC AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black (583 mm vs 47 mm). PDU types: Basic on the APC AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black, Switched on the Vertiv Knürr DIS Rack PDU, Compact, 0U, input GST18. Rack capacity: 0U/2U on the APC AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black, 1U on the Vertiv Knürr DIS Rack PDU, Compact, 0U, input GST18.

  • PDU types
    • AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black:Basic
    • Knürr DIS Rack PDU, Compact, 0U, input GST18:Switched
  • Rack capacity
    • AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black:0U/2U
    • Knürr DIS Rack PDU, Compact, 0U, input GST18:1U
  • Product colour
    • AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black:Black
    • Knürr DIS Rack PDU, Compact, 0U, input GST18:White
  • AC outlets quantity
    • AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black:14 AC outlet(s)
    • Knürr DIS Rack PDU, Compact, 0U, input GST18:6 AC outlet(s)
  • Power plug
    • AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black:C20 coupler
    • Knürr DIS Rack PDU, Compact, 0U, input GST18:GST18
  • AC outlet types
    • AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black:C13 coupler
    • Knürr DIS Rack PDU, Compact, 0U, input GST18:Type F
  • Input connection type
    • AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black:IEC-320 C20
    • Knürr DIS Rack PDU, Compact, 0U, input GST18:GST18
  • Nominal input voltage
    • AP6003A power distribution unit (PDU) 14 AC outlet(s) 0U/2U Black:230 V
    • Knürr DIS Rack PDU, Compact, 0U, input GST18:100-240 V

Side by side

Differences highlightedShow differences only (off)
Comparison of AP6003A, 03.302.206.1
36 specifications
Design3 differ
PDU typesDiffersBasicSwitched
TypeKnown for oneSingle-phaseUnknown — not stated by the source
Rack capacityDiffers0U/2U1U
MountingKnown for oneHorizontal/VerticalUnknown — not stated by the source
Product colourDiffersBlackWhite
Housing materialKnown for oneUnknown — not stated by the sourceBrass, Plastic, Steel, Zinc
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces4 differ
AC outlets quantityDiffers14 AC outlet(s)6 AC outlet(s)
Power plugDiffersC20 couplerGST18
AC outlet typesDiffersC13 couplerType F
Input connection typeDiffersIEC-320 C20GST18
Power2 differ
Nominal input voltageDiffers230 V100-240 V
AC input frequencyKnown for one50 - 60 HzUnknown — not stated by the source
Maximum currentDiffers20 A16 A
Nominal output voltageKnown for one100-240 VUnknown — not stated by the source
Load capacityKnown for one3680 VAUnknown — not stated by the source
Maximum input current per phaseKnown for one16 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one16 AUnknown — not stated by the source
Maximum powerKnown for one3680 WUnknown — not stated by the source
Certificates1 differ
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationDifferscUL, UL, REACH- CE Label in accordance with low voltage directive 2006/95/EEC EMC Directive 2006/108/EEC - Innova-GS - CB-scheme - VDE
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 50 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers56 mm44.4 mm
DepthDiffers47 mm583 mm
HeightDiffers523 mm45.5 mm
WeightKnown for one1.88 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one2.55 kgUnknown — not stated by the source
Package widthKnown for one123 mmUnknown — not stated by the source
Package depthKnown for one107 mmUnknown — not stated by the source
Package heightKnown for one612 mmUnknown — not stated by the source
Packaging contentidentical
Packaging contentKnown for oneUnknown — not stated by the source1 socket strip 2 mounting brackets

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons