Product comparison · 2 power distribution units (pdus)

APC 3-Pole Circuit Breaker, 70A, T1 Type for Symmetra PX250/500kW vs Vertiv PM 2000 Vertical Model

Add a product
  • 6specifications compared
  • 6differ
  • 0identical
  • 17known for one product only

Key differences

  • Output connections
    • 3-Pole Circuit Breaker, 70A, T1 Type for Symmetra PX250/500kW:1 x Hard Wire 3-wire (3PH)
    • PM 2000 Vertical Model:(21) C13 (3) C19
  • Maximum total current draw per phase
    • 3-Pole Circuit Breaker, 70A, T1 Type for Symmetra PX250/500kW:70 A
    • PM 2000 Vertical Model:24 A
  • Operating temperature (T-T)
    • 3-Pole Circuit Breaker, 70A, T1 Type for Symmetra PX250/500kW:0 - 40 °C
    • PM 2000 Vertical Model:10 - 45 °C
  • Storage temperature (T-T)
    • 3-Pole Circuit Breaker, 70A, T1 Type for Symmetra PX250/500kW:-15 - 40 °C
    • PM 2000 Vertical Model:-40 - 65 °C
  • Weight (imperial)
    • 3-Pole Circuit Breaker, 70A, T1 Type for Symmetra PX250/500kW:1.81 kg (4 lbs)
    • PM 2000 Vertical Model:6.71 kg (14.8 lbs)

Side by side

Differences highlightedShow differences only (off)
Comparison of 3-Pole Circuit Breaker, 70A, T1 Type for Symmetra PX250/500kW, PM 2000 Vertical Model
23 specifications
Designidentical
MountingKnown for oneUnknown — not stated by the sourceVertical
Product colourKnown for oneUnknown — not stated by the sourceBlack
Ports & interfaces1 differ
Input connection typeKnown for oneUnknown — not stated by the sourceL21-30P
Output connectionsDiffers1 x Hard Wire 3-wire (3PH)(21) C13 (3) C19
I/O portsKnown for oneUnknown — not stated by the source1 x 10/100/1000 Ethernet 2 x RJ-45
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source3 m
Power1 differ
Nominal input voltageKnown for oneUnknown — not stated by the source208 V
Maximum currentKnown for oneUnknown — not stated by the source30 A
Maximum total current draw per phaseDiffers70 A24 A
AC input frequencyKnown for one60 HzUnknown — not stated by the source
Maximum input current per phaseKnown for one70 AUnknown — not stated by the source
Certificates1 differ
CertificationDiffersCE, UL Listed RoHSUL, FCC, cUL, CE, VCCI, C-Tick, CB
Operational conditions2 differ
Operating temperature (T-T)Differs0 - 40 °C10 - 45 °C
Storage temperature (T-T)Differs-15 - 40 °C-40 - 65 °C
Weight & dimensions1 differ
WidthKnown for oneUnknown — not stated by the source5.6 mm
DepthKnown for oneUnknown — not stated by the source8 mm
HeightKnown for oneUnknown — not stated by the source167.6 mm
Weight (imperial)Differs1.81 kg (4 lbs)6.71 kg (14.8 lbs)
WeightKnown for one1.82 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one2.7 kgUnknown — not stated by the source
Package widthKnown for one559 mmUnknown — not stated by the source
Package depthKnown for one546 mmUnknown — not stated by the source
Package heightKnown for one432 mmUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.