Product comparison · 2 power distribution units (pdus)

APC 3 Pole 5 Wire RCD 16A 30mA IEC309 vs Vertiv Cyclades PM20i-16A, Vertical

Add a product
  • 3specifications compared
  • 3differ
  • 0identical
  • 22known for one product only

Key differences

  • Input connection type
    • 3 Pole 5 Wire RCD 16A 30mA IEC309:IEC 309 16A 3P+N+PE
    • Cyclades PM20i-16A, Vertical:IEC 320-C20
  • Output connections
    • 3 Pole 5 Wire RCD 16A 30mA IEC309:1 x IEC 309 16A
    • Cyclades PM20i-16A, Vertical:(20)IEC320-C13
  • Weight
    • 3 Pole 5 Wire RCD 16A 30mA IEC309:1.7 kg
    • Cyclades PM20i-16A, Vertical:6.4 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of 3 Pole 5 Wire RCD 16A 30mA IEC309, Cyclades PM20i-16A, Vertical
25 specifications
Designidentical
MountingKnown for oneUnknown — not stated by the sourceVertical
Product colourKnown for oneUnknown — not stated by the sourceBlack
Ports & interfaces2 differ
Input connection typeDiffersIEC 309 16A 3P+N+PEIEC 320-C20
Output connectionsDiffers1 x IEC 309 16A(20)IEC320-C13
I/O portsKnown for oneUnknown — not stated by the source2 x RS-232
Poweridentical
Maximum currentKnown for oneUnknown — not stated by the source16 A
Nominal input voltageKnown for one400 VUnknown — not stated by the source
AC input frequencyKnown for one50 HzUnknown — not stated by the source
Nominal output voltageKnown for one400 VUnknown — not stated by the source
Maximum input current per phaseKnown for one16 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one16 AUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceFCC Class A, CSA (UL), EN55022, A (CE), EN55024, EN60950, C-Tick
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source-40 - 85 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source10 - 50 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Weight & dimensions1 differ
WidthKnown for oneUnknown — not stated by the source50.8 mm
DepthKnown for oneUnknown — not stated by the source71.1 mm
HeightKnown for oneUnknown — not stated by the source1676.4 mm
WeightDiffers1.7 kg6.4 kg
Weight (imperial)Known for oneUnknown — not stated by the source6.4 kg (14.1 lbs)
Featuresidentical
Cable lengthKnown for one1.4 mUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one2.6 kgUnknown — not stated by the source
Package widthKnown for one432 mmUnknown — not stated by the source
Package depthKnown for one406 mmUnknown — not stated by the source
Package heightKnown for one254 mmUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons