  • PDU types
    • 22kVA PDU:Metered
    • PDPM100G6F-M power distribution unit (PDU) Black:Basic
  • Nominal input voltage
    • 22kVA PDU:400 V
    • PDPM100G6F-M power distribution unit (PDU) Black:480 V
  • AC input frequency
    • 22kVA PDU:50 - 60 Hz
    • PDPM100G6F-M power distribution unit (PDU) Black:60 Hz
  • Maximum current
    • 22kVA PDU:32 A
    • PDPM100G6F-M power distribution unit (PDU) Black:159 A
  • Nominal output voltage
    • 22kVA PDU:240 V
    • PDPM100G6F-M power distribution unit (PDU) Black:120-208 V
  • Load capacity
    • 22kVA PDU:23000 VA
    • PDPM100G6F-M power distribution unit (PDU) Black:100000 VA
  • Maximum input current per phase
    • 22kVA PDU:32 A
    • PDPM100G6F-M power distribution unit (PDU) Black:146 A
  • Operating temperature (T-T)
    • 22kVA PDU:-5 - 60 °C
    • PDPM100G6F-M power distribution unit (PDU) Black:0 - 40 °C

Side by side

Differences highlightedShow differences only (on)
Comparison of 22kVA PDU, PDPM100G6F-M
27 specifications
Design1 differ
PDU typesDiffersMeteredBasic
Ports & interfacesidentical
AC outlets quantityKnown for one24 AC outlet(s)Unknown — not stated by the source
Featuresidentical
Cable lengthKnown for one0.91 mUnknown — not stated by the source
Power6 differ
Nominal input voltageDiffers400 V480 V
AC input frequencyDiffers50 - 60 Hz60 Hz
Maximum currentDiffers32 A159 A
Nominal output voltageDiffers240 V120-208 V
Load capacityDiffers23000 VA100000 VA
Maximum input current per phaseDiffers32 A146 A
Maximum total current draw per phaseKnown for oneUnknown — not stated by the source278 A
Certificates1 differ
CertificationDifferscULCSA C22.2 No. 60950-1-03,FCC 15 B,UL 60950-1
Operational conditions5 differ
Operating temperature (T-T)Differs-5 - 60 °C0 - 40 °C
Storage temperature (T-T)Differs-25 - 65 °C0 - 95 °C
Operating relative humidity (H-H)Differs5 - 95%-15 - 40%
Storage relative humidity (H-H)Differs5 - 95%0 - 95%
Non-operating altitudeDiffers0 - 15000 m0 - 4500 m
Weight & dimensions4 differ
WidthDiffers56 mm600 mm
DepthDiffers75 mm1070 mm
HeightDiffers1778 mm2007 mm
WeightDiffers9.55 kg818.2 kg
Packaging data3 differ
Package widthDiffers152 mm1016 mm
Package depthDiffers127 mm1220 mm
Package heightDiffers2134 mm2150 mm