Product comparison · 2 power distribution units (pdus)

APC 125KVA PDU w/ 480 PRI 208/120 SEC K 20 XMER vs APC IT Power Distribution Module 3x1 Pole 3 Wire 20A 240V IEC309 260cm 380cm 500cm

Add a product
  • 16specifications compared
  • 14differ
  • 2identical
  • 10known for one product only

Key differences

The APC 125KVA PDU w/ 480 PRI 208/120 SEC K 20 XMER has 240 V more nominal input voltage than the APC IT Power Distribution Module 3x1 Pole 3 Wire 20A 240V IEC309 260cm 380cm 500cm (480 V vs 240 V). The APC 125KVA PDU w/ 480 PRI 208/120 SEC K 20 XMER has 130 A more maximum input current per phase than the APC IT Power Distribution Module 3x1 Pole 3 Wire 20A 240V IEC309 260cm 380cm 500cm (150 A vs 20 A). The APC 125KVA PDU w/ 480 PRI 208/120 SEC K 20 XMER has 482 mm more width than the APC IT Power Distribution Module 3x1 Pole 3 Wire 20A 240V IEC309 260cm 380cm 500cm (914 mm vs 432 mm). PDU types: Basic on the APC 125KVA PDU w/ 480 PRI 208/120 SEC K 20 XMER, Metered, Monitored on the APC IT Power Distribution Module 3x1 Pole 3 Wire 20A 240V IEC309 260cm 380cm 500cm. Product colour: Black on the APC 125KVA PDU w/ 480 PRI 208/120 SEC K 20 XMER, Grey on the APC IT Power Distribution Module 3x1 Pole 3 Wire 20A 240V IEC309 260cm 380cm 500cm.

  • PDU types
    • 125KVA PDU w/ 480 PRI 208/120 SEC K 20 XMER:Basic
    • IT Power Distribution Module 3x1 Pole 3 Wire 20A 240V IEC309 260cm 380cm 500cm:Metered, Monitored
  • Product colour
    • 125KVA PDU w/ 480 PRI 208/120 SEC K 20 XMER:Black
    • IT Power Distribution Module 3x1 Pole 3 Wire 20A 240V IEC309 260cm 380cm 500cm:Grey
  • Nominal input voltage
    • 125KVA PDU w/ 480 PRI 208/120 SEC K 20 XMER:480 V
    • IT Power Distribution Module 3x1 Pole 3 Wire 20A 240V IEC309 260cm 380cm 500cm:240 V
  • Nominal output voltage
    • 125KVA PDU w/ 480 PRI 208/120 SEC K 20 XMER:120-208 V
    • IT Power Distribution Module 3x1 Pole 3 Wire 20A 240V IEC309 260cm 380cm 500cm:240 V
  • Maximum input current per phase
    • 125KVA PDU w/ 480 PRI 208/120 SEC K 20 XMER:150 A
    • IT Power Distribution Module 3x1 Pole 3 Wire 20A 240V IEC309 260cm 380cm 500cm:20 A
  • Certification
    • 125KVA PDU w/ 480 PRI 208/120 SEC K 20 XMER:UL 60950
    • IT Power Distribution Module 3x1 Pole 3 Wire 20A 240V IEC309 260cm 380cm 500cm:UL
  • Width
    • 125KVA PDU w/ 480 PRI 208/120 SEC K 20 XMER:914 mm
    • IT Power Distribution Module 3x1 Pole 3 Wire 20A 240V IEC309 260cm 380cm 500cm:432 mm
  • Depth
    • 125KVA PDU w/ 480 PRI 208/120 SEC K 20 XMER:813 mm
    • IT Power Distribution Module 3x1 Pole 3 Wire 20A 240V IEC309 260cm 380cm 500cm:419 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of 125KVA PDU w/ 480 PRI 208/120 SEC K 20 XMER, IT Power Distribution Module 3x1 Pole 3 Wire 20A 240V IEC309 260cm 380cm 500cm
26 specifications
Design2 differ
PDU typesDiffersBasicMetered, Monitored
Product colourDiffersBlackGrey
DisplayKnown for oneLCDUnknown — not stated by the source
Ports & interfacesidentical
AC outlets quantityKnown for oneUnknown — not stated by the source3 AC outlet(s)
Serial ports quantityKnown for oneUnknown — not stated by the source0
Output connectionsKnown for oneUnknown — not stated by the source3 x IEC 309
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceWeb/SNMP
Power3 differ
Nominal input voltageDiffers480 V240 V
Nominal output voltageDiffers120-208 V240 V
Maximum input current per phaseDiffers150 A20 A
Maximum total current draw per phaseKnown for oneUnknown — not stated by the source20 A
Load capacityKnown for one125000 VAUnknown — not stated by the source
Certificates1 differ
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
CertificationDiffersUL 60950UL
Weight & dimensions4 differ
WidthDiffers914 mm432 mm
DepthDiffers813 mm419 mm
HeightDiffers2070 mm152 mm
WeightDiffers779.5 kg3.69 kg
Packaging data4 differ
Package weightDiffers802.3 kg4.6 kg
Package widthDiffers1194 mm432 mm
Package depthDiffers1168 mm419 mm
Package heightDiffers2235 mm152 mm
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.