Product comparison · 2 power distribution units (pdus)

APC 100kW Modular Power Distribution Unit vs APC IT Power Distribution Module 3 Pole 5 Wire 40A IEC 309 560cm

Add a product
  • 16specifications compared
  • 15differ
  • 1identical
  • 8known for one product only

Key differences

  • PDU types
    • 100kW Modular Power Distribution Unit:Basic
    • IT Power Distribution Module 3 Pole 5 Wire 40A IEC 309 560cm:Metered, Monitored
  • Product colour
    • 100kW Modular Power Distribution Unit:Black
    • IT Power Distribution Module 3 Pole 5 Wire 40A IEC 309 560cm:Grey
  • Output connections
    • 100kW Modular Power Distribution Unit:1 x 4-wire
    • IT Power Distribution Module 3 Pole 5 Wire 40A IEC 309 560cm:1 x IEC 309
  • Nominal input voltage
    • 100kW Modular Power Distribution Unit:208 V
    • IT Power Distribution Module 3 Pole 5 Wire 40A IEC 309 560cm:230 V
  • Nominal output voltage
    • 100kW Modular Power Distribution Unit:208 V
    • IT Power Distribution Module 3 Pole 5 Wire 40A IEC 309 560cm:230 V
  • Maximum input current per phase
    • 100kW Modular Power Distribution Unit:332 A
    • IT Power Distribution Module 3 Pole 5 Wire 40A IEC 309 560cm:40 A
  • Maximum total current draw per phase
    • 100kW Modular Power Distribution Unit:278 A
    • IT Power Distribution Module 3 Pole 5 Wire 40A IEC 309 560cm:4 A
  • Width
    • 100kW Modular Power Distribution Unit:600 mm
    • IT Power Distribution Module 3 Pole 5 Wire 40A IEC 309 560cm:445 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of 100kW Modular Power Distribution Unit, IT Power Distribution Module 3 Pole 5 Wire 40A IEC 309 560cm
24 specifications
Design2 differ
PDU typesDiffersBasicMetered, Monitored
Product colourDiffersBlackGrey
Ports & interfaces1 differ
Input connection typeKnown for one5-wireUnknown — not stated by the source
Output connectionsDiffers1 x 4-wire1 x IEC 309
AC outlets quantityKnown for oneUnknown — not stated by the source1 AC outlet(s)
Featuresidentical
LED indicatorsKnown for oneYesUnknown — not stated by the source
Cable lengthKnown for oneUnknown — not stated by the source0.56 m
Power4 differ
Nominal input voltageDiffers208 V230 V
AC input frequencyKnown for one60 HzUnknown — not stated by the source
Nominal output voltageDiffers208 V230 V
Load capacityKnown for one100000 VAUnknown — not stated by the source
Maximum input current per phaseDiffers332 A40 A
Maximum total current draw per phaseDiffers278 A4 A
Certificatesidentical
CertificationULUL
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Weight & dimensions4 differ
WidthDiffers600 mm445 mm
DepthDiffers1070 mm406 mm
HeightDiffers2004 mm127 mm
WeightDiffers409.1 kg6.27 kg
Packaging data4 differ
Package weightDiffers454.6 kg6.82 kg
Package widthDiffers1016 mm444 mm
Package depthDiffers1220 mm406 mm
Package heightDiffers2150 mm127 mm
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceWeb/SNMP

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons