Product comparison · 2 maintenance bypass panels (mbps)

APC SRYLSBP20KP maintenance bypass panel (MBP) 200 vs Salicru BM-R 63 A+

Add a product
  • 11specifications compared
  • 9differ
  • 2identical
  • 10known for one product only

Key differences

  • Rack capacity
    • SRYLSBP20KP maintenance bypass panel (MBP) 200:4U
    • BM-R 63 A+:2U
  • Maximum current
    • SRYLSBP20KP maintenance bypass panel (MBP) 200:125 A
    • BM-R 63 A+:63 A
  • Operation voltage range
    • SRYLSBP20KP maintenance bypass panel (MBP) 200:200 - 240 V
    • BM-R 63 A+:208 - 240 V
  • Operating temperature (T-T)
    • SRYLSBP20KP maintenance bypass panel (MBP) 200:0 - 40 °C
    • BM-R 63 A+:0 - 45 °C
  • Maximum operating altitude
    • SRYLSBP20KP maintenance bypass panel (MBP) 200:3000 m
    • BM-R 63 A+:2400 m
  • Width
    • SRYLSBP20KP maintenance bypass panel (MBP) 200:432 mm
    • BM-R 63 A+:440 mm
  • Depth
    • SRYLSBP20KP maintenance bypass panel (MBP) 200:755 mm
    • BM-R 63 A+:80 mm
  • Height
    • SRYLSBP20KP maintenance bypass panel (MBP) 200:175 mm
    • BM-R 63 A+:85 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of SRYLSBP20KP, BM-R 63 A+
21 specifications
Features1 differ
Housing colourBlackBlack
Number of output IEC jumpersKnown for oneUnknown — not stated by the source6
Recommended cableKnown for oneUnknown — not stated by the source10 mm²
Rack capacityDiffers4U2U
Rack mountingYesYes
Wall mountableKnown for oneUnknown — not stated by the sourceYes
Compatible rack widthKnown for oneUnknown — not stated by the source19"
Ports & interfacesidentical
UPS inputKnown for oneUnknown — not stated by the sourceTerminals
UPS outputKnown for oneUnknown — not stated by the sourceTerminal + 2x IEC19 + 2x IEC13
Power2 differ
Maximum currentDiffers125 A63 A
Operation voltage rangeDiffers200 - 240 V208 - 240 V
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Sustainabilityidentical
Doesn't containKnown for oneUnknown — not stated by the sourceLead, Mercury, Cadmium
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Operational conditions2 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 45 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Maximum operating altitudeDiffers3000 m2400 m
Weight & dimensions4 differ
WidthDiffers432 mm440 mm
DepthDiffers755 mm80 mm
HeightDiffers175 mm85 mm
WeightDiffers23 kg2.4 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.