Product comparison · 2 uninterruptible power supplies (upss)

Legrand UPS DAKER DK PLUS 10000VA 3/1 NO BATT vs Legrand UPS DAKER DK PLUS 6000VA NO BATT

Add a product
  • 62specifications compared
  • 20differ
  • 42identical
  • 0known for one product only

Key differences

  • Output power capacity
    • UPS DAKER DK PLUS 10000VA 3/1 NO BATT:10 kVA
    • UPS DAKER DK PLUS 6000VA NO BATT:6 kVA
  • Output power
    • UPS DAKER DK PLUS 10000VA 3/1 NO BATT:9000 W
    • UPS DAKER DK PLUS 6000VA NO BATT:6000 W
  • Number of input phases
    • UPS DAKER DK PLUS 10000VA 3/1 NO BATT:3
    • UPS DAKER DK PLUS 6000VA NO BATT:1
  • Efficiency
    • UPS DAKER DK PLUS 10000VA 3/1 NO BATT:90%
    • UPS DAKER DK PLUS 6000VA NO BATT:94%
  • Efficiency (ECO mode)
    • UPS DAKER DK PLUS 10000VA 3/1 NO BATT:98%
    • UPS DAKER DK PLUS 6000VA NO BATT:97%
  • Power factor
    • UPS DAKER DK PLUS 10000VA 3/1 NO BATT:0.9
    • UPS DAKER DK PLUS 6000VA NO BATT:1
  • Output power factor
    • UPS DAKER DK PLUS 10000VA 3/1 NO BATT:0.9
    • UPS DAKER DK PLUS 6000VA NO BATT:1
  • Rack capacity
    • UPS DAKER DK PLUS 10000VA 3/1 NO BATT:3U
    • UPS DAKER DK PLUS 6000VA NO BATT:2U

Side by side

Differences highlightedShow differences only (off)
Comparison of UPS DAKER DK PLUS 10000VA 3/1 NO BATT, UPS DAKER DK PLUS 6000VA NO BATT
62 specifications
Features7 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers10 kVA6 kVA
Output powerDiffers9000 W6000 W
WaveformSineSine
Input operation voltage (min)176 V176 V
Input operation voltage (max)280 V280 V
Input frequency47/63 Hz47/63 Hz
Output operation voltage (min)228 V228 V
Output operation voltage (max)232 V232 V
Output frequency50/60 Hz50/60 Hz
Output voltage regulation1%1%
Surge energy rating1900 J1900 J
Number of input phasesDiffers31
Number of output phases11
EfficiencyDiffers90%94%
Efficiency (ECO mode)Differs98%97%
Power factorDiffers0.91
Input power factor0.990.99
Output power factorDiffers0.91
Crest factor3:13:1
Emergency Power Off (EPO)YesYes
Output voltage Total Harmonic Distortion (THD)3%3%
Input current Total Harmonic Distortion (THD)3%3%
Noise level50 dB50 dB
Management protocolsNetwork management,Simple Network Management Protocol (SNMP)Network management,Simple Network Management Protocol (SNMP)
Potential-free outputNoNo
Auto shut-offNoNo
Detachable power cordYesYes
Power source typeACAC
Ports & interfacesidentical
AC outlet typesHardwireHardwire
Power plugHardwireHardwire
AC outlets quantity1 AC outlet(s)1 AC outlet(s)
USB portYesYes
Serial interfaceYesYes
Serial interface typeRS-232RS-232
Design1 differ
Form factorRackmountRackmount
Product colourBlackBlack
Rack capacityDiffers3U2U
Display typeLCDLCD
LED indicatorsStatusStatus
International Protection (IP) codeIP20IP20
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Certificatesidentical
CertificationEN 62040-1, EN 62040-2, EN 62040-3EN 62040-1, EN 62040-2, EN 62040-3
Weight & dimensions2 differ
WidthDiffers132 mm88 mm
Depth680 mm680 mm
Height440 mm440 mm
WeightDiffers28 kg25 kg
Packaging data3 differ
Package widthDiffers132 mm88 mm
Package depthDiffers39.5 mm26.3 mm
Package height440 mm440 mm
Package weightDiffers30.6 kg18.8 kg
Logistics data7 differ
Products per palletDiffers4 pc(s)6 pc(s)
Pallet net heightDiffers95 cm83 cm
Pallet net length100 cm100 cm
Pallet net weightDiffers128.8 kg118.8 kg
Pallet net width120 cm120 cm
Master (outer) case widthDiffers560 mm565 mm
Master (outer) case lengthDiffers890 mm860 mm
Master (outer) case heightDiffers265 mm220 mm
Master (outer) case gross weightDiffers32.2 kg19.8 kg
Products per master (outer) case1 pc(s)1 pc(s)

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.