Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OL1000EXL uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA vs CyberPower PR2200ELCDSL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA

Add a product
  • 35specifications compared
  • 17differ
  • 18identical
  • 19known for one product only

Key differences

  • UPS topology
    • OL1000EXL uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:Double-conversion (Online)
    • PR2200ELCDSL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:Line-Interactive
  • Output power capacity
    • OL1000EXL uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:1 kVA
    • PR2200ELCDSL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:2.2 kVA
  • Output power
    • OL1000EXL uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:900 W
    • PR2200ELCDSL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:1980 W
  • Input operation voltage (min)
    • OL1000EXL uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:120 V
    • PR2200ELCDSL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:160 V
  • Input operation voltage (max)
    • OL1000EXL uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:280 V
    • PR2200ELCDSL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:283 V
  • Input frequency
    • OL1000EXL uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:40/70 Hz
    • PR2200ELCDSL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:50/60 Hz
  • Management protocols
    • OL1000EXL uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:SNMP/HTTP
    • PR2200ELCDSL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:SNMP, HTTP
  • AC outlet types
    • OL1000EXL uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:C13 coupler
    • PR2200ELCDSL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:C13 coupler, C19 coupler

Side by side

Differences highlightedShow differences only (on)
Comparison of OL1000EXL, PR2200ELCDSL
54 specifications
Features7 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers1 kVA2.2 kVA
Output powerDiffers900 W1980 W
Input operation voltage (min)Differs120 V160 V
Input operation voltage (max)Differs280 V283 V
Input frequencyDiffers40/70 Hz50/60 Hz
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Response timeKnown for oneUnknown — not stated by the source4 ms
Number of input phasesKnown for oneUnknown — not stated by the source1
Number of output phasesKnown for oneUnknown — not stated by the source1
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Management protocolsDiffersSNMP/HTTPSNMP, HTTP
Output operation voltage (min)Known for one200 VUnknown — not stated by the source
Output operation voltage (max)Known for one240 VUnknown — not stated by the source
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
Surge protection featuresKnown for oneFax, Modem, Network, TelephoneUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Power plugKnown for oneUnknown — not stated by the sourceC20 coupler
AC outlets quantityDiffers6 AC outlet(s)9 AC outlet(s)
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
Battery4 differ
Number of batteries supportedDiffers34
Typical backup time at full loadDiffers6 min3 min
Typical backup time at half loadDiffers17 min12 min
Battery recharge timeDiffers4 h8 h
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Designidentical
Cooling typeKnown for oneActiveUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers167 mm170 mm
DepthDiffers397 mm432 mm
HeightDiffers232 mm221 mm
WeightDiffers17 kg23.3 kg
Other featuresidentical
Output connectionsKnown for oneUnknown — not stated by the source8 x IEC 320 C13, 1 x IEC 320 C19
Nominal input voltageKnown for oneUnknown — not stated by the source230 V
Nominal output voltageKnown for oneUnknown — not stated by the source230 V
Suitable for use in country/locationKnown for oneUnknown — not stated by the sourceEurope
Logistics dataidentical
Harmonized System (HS) codeKnown for one85078000Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons