Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OL1000EXL uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA vs CyberPower PR2200ELCDSL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA

Add a product
  • 35specifications compared
  • 17differ
  • 18identical
  • 19known for one product only

Key differences

  • UPS topology
    • OL1000EXL uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:Double-conversion (Online)
    • PR2200ELCDSL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:Line-Interactive
  • Output power capacity
    • OL1000EXL uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:1 kVA
    • PR2200ELCDSL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:2.2 kVA
  • Output power
    • OL1000EXL uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:900 W
    • PR2200ELCDSL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:1980 W
  • Input operation voltage (min)
    • OL1000EXL uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:120 V
    • PR2200ELCDSL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:160 V
  • Input operation voltage (max)
    • OL1000EXL uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:280 V
    • PR2200ELCDSL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:283 V
  • Input frequency
    • OL1000EXL uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:40/70 Hz
    • PR2200ELCDSL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:50/60 Hz
  • Management protocols
    • OL1000EXL uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:SNMP/HTTP
    • PR2200ELCDSL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:SNMP, HTTP
  • AC outlet types
    • OL1000EXL uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:C13 coupler
    • PR2200ELCDSL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:C13 coupler, C19 coupler

Side by side

Differences highlightedShow differences only (off)
Comparison of OL1000EXL, PR2200ELCDSL
54 specifications
Features7 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers1 kVA2.2 kVA
Output powerDiffers900 W1980 W
WaveformSineSine
Input operation voltage (min)Differs120 V160 V
Input operation voltage (max)Differs280 V283 V
Input frequencyDiffers40/70 Hz50/60 Hz
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Response timeKnown for oneUnknown — not stated by the source4 ms
Number of input phasesKnown for oneUnknown — not stated by the source1
Number of output phasesKnown for oneUnknown — not stated by the source1
Emergency Power Off (EPO)YesYes
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Surge protectionYesYes
Power protection featuresOverloadOverload
Audible alarm(s)YesYes
Web-based managementYesYes
Management protocolsDiffersSNMP/HTTPSNMP, HTTP
Auto-restartYesYes
Output operation voltage (min)Known for one200 VUnknown — not stated by the source
Output operation voltage (max)Known for one240 VUnknown — not stated by the source
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
Surge protection featuresKnown for oneFax, Modem, Network, TelephoneUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Power plugKnown for oneUnknown — not stated by the sourceC20 coupler
AC outlets quantityDiffers6 AC outlet(s)9 AC outlet(s)
USB 2.0 ports quantity11
Serial ports quantity11
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
Battery4 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Battery capacity9 Ah9 Ah
Battery voltage12 V12 V
Number of batteries supportedDiffers34
Typical backup time at full loadDiffers6 min3 min
Typical backup time at half loadDiffers17 min12 min
Battery recharge timeDiffers4 h8 h
Automatic battery testYesYes
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Designidentical
Form factorTowerTower
Product colourBlackBlack
Display typeLCDLCD
LED indicatorsYesYes
Cooling typeKnown for oneActiveUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers167 mm170 mm
DepthDiffers397 mm432 mm
HeightDiffers232 mm221 mm
WeightDiffers17 kg23.3 kg
Packaging dataidentical
Bundled softwarePowerPanel Business EditionPowerPanel Business Edition
Other featuresidentical
Output connectionsKnown for oneUnknown — not stated by the source8 x IEC 320 C13, 1 x IEC 320 C19
Nominal input voltageKnown for oneUnknown — not stated by the source230 V
Nominal output voltageKnown for oneUnknown — not stated by the source230 V
Suitable for use in country/locationKnown for oneUnknown — not stated by the sourceEurope
Logistics dataidentical
Harmonized System (HS) codeKnown for one85078000Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.