The CyberPower HSTP3T20K100P10M uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA has 10 kVA more output power capacity than the CyberPower OLS10KERT5UM uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA (20 kVA vs 10 kVA). The CyberPower HSTP3T20K100P10M uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA has 8,000 W more output power than the CyberPower OLS10KERT5UM uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA (18000 W vs 10000 W). The CyberPower HSTP3T20K100P10M uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA has 12 V more output operation voltage (min) than the CyberPower OLS10KERT5UM uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA (220 V vs 208 V). Input frequency: 40/70 Hz on the CyberPower HSTP3T20K100P10M uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA, 50/60 Hz on the CyberPower OLS10KERT5UM uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA. Serial interface type: RS-232, RS-485 on the CyberPower HSTP3T20K100P10M uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA, RS-232 on the CyberPower OLS10KERT5UM uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA.

  • Output power capacity
    • HSTP3T20K100P10M uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA:20 kVA
    • OLS10KERT5UM uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:10 kVA
  • Output power
    • HSTP3T20K100P10M uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA:18000 W
    • OLS10KERT5UM uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:10000 W
  • Input frequency
    • HSTP3T20K100P10M uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA:40/70 Hz
    • OLS10KERT5UM uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:50/60 Hz
  • Output operation voltage (min)
    • HSTP3T20K100P10M uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA:220 V
    • OLS10KERT5UM uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:208 V
  • Output operation voltage (max)
    • HSTP3T20K100P10M uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA:415 V
    • OLS10KERT5UM uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:240 V
  • Maximum current
    • HSTP3T20K100P10M uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA:42 A
    • OLS10KERT5UM uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:45.5 A
  • Output voltage Total Harmonic Distortion (THD)
    • HSTP3T20K100P10M uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA:5.5%
    • OLS10KERT5UM uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:3%
  • Serial interface type
    • HSTP3T20K100P10M uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA:RS-232, RS-485
    • OLS10KERT5UM uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:RS-232

Side by side

Differences highlightedShow differences only (on)
Comparison of HSTP3T20K100P10M, OLS10KERT5UM
70 specifications
Features8 differ
Output power capacityDiffers20 kVA10 kVA
Output powerDiffers18000 W10000 W
Input operation voltage (min)Known for oneUnknown — not stated by the source110 V
Input operation voltage (max)Known for oneUnknown — not stated by the source300 V
Input frequencyDiffers40/70 Hz50/60 Hz
Output operation voltage (min)Differs220 V208 V
Output operation voltage (max)Differs415 V240 V
Maximum currentDiffers42 A45.5 A
Surge energy ratingKnown for oneUnknown — not stated by the source1335 J
Response timeKnown for oneUnknown — not stated by the source0 ms
Power factorKnown for oneUnknown — not stated by the source1
Output voltage Total Harmonic Distortion (THD)Differs5.5%3%
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Audible alarm modesDiffersAlarm when on battery, Battery replacement, Fault, Low battery alarm, Overload alarmAlarm when on battery, Fault, Low battery alarm, Overload alarm
Number of input phasesKnown for one3Unknown — not stated by the source
EfficiencyKnown for one95%Unknown — not stated by the source
Output power factorKnown for one0.9Unknown — not stated by the source
ECO modeKnown for oneYesUnknown — not stated by the source
Noise levelKnown for one58 dBUnknown — not stated by the source
Ports & interfaces1 differ
AC outlet typesKnown for oneUnknown — not stated by the sourceC13 coupler, C19 coupler
AC outlets quantityKnown for oneUnknown — not stated by the source8 AC outlet(s)
USB portKnown for oneUnknown — not stated by the sourceYes
Serial interface typeDiffersRS-232, RS-485RS-232
Serial ports quantityKnown for oneUnknown — not stated by the source1
Serial interfaceKnown for oneYesUnknown — not stated by the source
Emergency Power Off (EPO) connectorKnown for oneYesUnknown — not stated by the source
Battery3 differ
Number of batteries supportedDiffers4010
Typical backup time at full loadDiffers5.5 min2.9 min
Typical backup time at half loadDiffers18 min11.2 min
Battery recharge timeKnown for oneUnknown — not stated by the source4 h
Charging currentKnown for oneUnknown — not stated by the source4 A
Battery capacityKnown for one12 AhUnknown — not stated by the source
Battery voltageKnown for one12 VUnknown — not stated by the source
Design2 differ
Form factorDiffersTowerRackmount/Tower
Rack capacityKnown for oneUnknown — not stated by the source5U
LED indicatorsDiffersYesOperation
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Operational conditions1 differ
Storage temperature (T-T)Differs-40 - 70 °C-15 - 45 °C
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15000 m
Packaging contentidentical
Cables includedKnown for oneUnknown — not stated by the sourceUSB cable
ManualKnown for oneYesUnknown — not stated by the source
Certificates1 differ
CertificationDiffersCE, IEC62040-1, IEC62040-2CE, RoHS
Weight & dimensions4 differ
WidthDiffers250 mm433 mm
DepthDiffers770 mm661 mm
HeightDiffers950 mm213.5 mm
WeightDiffers64 kg74 kg
Packaging data4 differ
Package widthDiffers400 mm600 mm
Package depthDiffers1140 mm800 mm
Package heightDiffers945 mm650 mm
Package weightDiffers88.5 kg82 kg
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source8504408690
Country of originKnown for oneUnknown — not stated by the sourceChina