Product comparison · 2 uninterruptible power supplies (upss)

CyberPower HSTP3T10KEBCWOB uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA vs CyberPower OL1000RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA

Add a product
  • 36specifications compared
  • 23differ
  • 13identical
  • 42known for one product only

Key differences

The CyberPower HSTP3T10KEBCWOB uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA has 9 kVA more output power capacity than the CyberPower OL1000RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA (10 kVA vs 1 kVA). The CyberPower HSTP3T10KEBCWOB uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA has 8,100 W more output power than the CyberPower OL1000RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA (9000 W vs 900 W). The CyberPower HSTP3T10KEBCWOB uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA has 160 V more input operation voltage (min) than the CyberPower OL1000RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA (220 V vs 60 V). Waveform: Pure sine on the CyberPower HSTP3T10KEBCWOB uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA, Sine on the CyberPower OL1000RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA. Input frequency: 50/60 Hz on the CyberPower HSTP3T10KEBCWOB uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA, 40/70 Hz on the CyberPower OL1000RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA.

  • Output power capacity
    • HSTP3T10KEBCWOB uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:10 kVA
    • OL1000RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:1 kVA
  • Output power
    • HSTP3T10KEBCWOB uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:9000 W
    • OL1000RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:900 W
  • Waveform
    • HSTP3T10KEBCWOB uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:Pure sine
    • OL1000RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:Sine
  • Input operation voltage (min)
    • HSTP3T10KEBCWOB uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:220 V
    • OL1000RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:60 V
  • Input operation voltage (max)
    • HSTP3T10KEBCWOB uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:415 V
    • OL1000RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:150 V
  • Input frequency
    • HSTP3T10KEBCWOB uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:50/60 Hz
    • OL1000RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:40/70 Hz
  • Output operation voltage (min)
    • HSTP3T10KEBCWOB uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:220 V
    • OL1000RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:100 V
  • Output operation voltage (max)
    • HSTP3T10KEBCWOB uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:415 V
    • OL1000RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:125 V

Side by side

Differences highlightedShow differences only (on)
Comparison of HSTP3T10KEBCWOB, OL1000RTXL2UN
78 specifications
Features9 differ
Output power capacityDiffers10 kVA1 kVA
Output powerDiffers9000 W900 W
WaveformDiffersPure sineSine
Input operation voltage (min)Differs220 V60 V
Input operation voltage (max)Differs415 V150 V
Input frequencyDiffers50/60 Hz40/70 Hz
Output operation voltage (min)Differs220 V100 V
Output operation voltage (max)Differs415 V125 V
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Output frequency regulationKnown for oneUnknown — not stated by the source0.25 Hz
Efficiency (ECO mode)Differs98%94%
Output power factorKnown for oneUnknown — not stated by the source0.9
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source3%
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Surge protection featuresKnown for oneUnknown — not stated by the sourceNetwork, Telephone
EfficiencyKnown for one95%Unknown — not stated by the source
Efficiency (Battery mode)Known for one95%Unknown — not stated by the source
Power factorKnown for one0.9Unknown — not stated by the source
Power Factor Correction (PFC) typeKnown for oneActiveUnknown — not stated by the source
Total Harmonic Distortion (THD) (linear load)Known for one1%Unknown — not stated by the source
Total Harmonic Distortion (THD) (non-linear load)Known for one5.5%Unknown — not stated by the source
Noise levelKnown for one58 dBUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Maximum number of paralleling UPSsKnown for one4Unknown — not stated by the source
Ports & interfacesidentical
AC outlet typesKnown for oneUnknown — not stated by the sourceNEMA 5–15R
Power plugKnown for oneUnknown — not stated by the sourceNEMA 5-15P
AC outlets quantityKnown for oneUnknown — not stated by the source8 AC outlet(s)
USB portKnown for oneUnknown — not stated by the sourceYes
Serial ports quantityKnown for oneUnknown — not stated by the source1
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
Serial interfaceKnown for oneYesUnknown — not stated by the source
Serial interface typeKnown for oneRS-485Unknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Battery2 differ
Battery capacityKnown for oneUnknown — not stated by the source9 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Number of battery cellsKnown for oneUnknown — not stated by the source3
Typical backup time at full loadDiffers12 min7.4 min
Typical backup time at half loadDiffers25 min20 min
Battery recharge timeKnown for oneUnknown — not stated by the source4 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Cold startKnown for oneUnknown — not stated by the sourceYes
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceRB1290X3L
Design2 differ
Form factorDiffersTowerRackmount/Tower
Housing materialDiffersMetalSteel
Rack capacityKnown for oneUnknown — not stated by the source2U
Cable lengthKnown for oneUnknown — not stated by the source3 m
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Operational conditions2 differ
Storage temperature (T-T)Differs-40 - 70 °C-20 - 45 °C
Operating relative humidity (H-H)Differs0 - 95%0 - 90%
Packaging contentidentical
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Cables includedKnown for oneUnknown — not stated by the sourcePhone (RJ-11), Serial, USB cable
ManualKnown for oneUnknown — not stated by the sourceYes
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
CertificationKnown for oneCE , IEC62040-1 , IEC62040-2Unknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceUL 1778 5th Ed.CSA C22.2 NO.107.3-05FCC Part 15 Class A CSA C22.2 NO.107.3-05 FCC Part 15 Class B
Weight & dimensions4 differ
WidthDiffers250 mm432 mm
DepthDiffers840 mm429 mm
HeightDiffers715 mm88 mm
WeightDiffers51.5 kg18 kg
Packaging data4 differ
Package widthDiffers400 mm546.1 mm
Package depthDiffers1000 mm571.5 mm
Package heightDiffers930 mm235.5 mm
Package weightDiffers60 kg24.27 g
Other featuresidentical
BypassKnown for oneAutomatic, ManualUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons