The CyberPower OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA has 1.575 kVA more output power capacity than the CyberPower CP425SLG uninterruptible power supply (UPS) 0.425 kVA (2 kVA vs 0.425 kVA). The CyberPower OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA has 1,065 W more output power than the CyberPower CP425SLG uninterruptible power supply (UPS) 0.425 kVA (1320 W vs 255 W). The CyberPower OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA has 1,170 J more surge energy rating than the CyberPower CP425SLG uninterruptible power supply (UPS) 0.425 kVA (2060 J vs 890 J). Only the CyberPower OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA has hot-swap battery. AC outlet types: NEMA 5–15R on the CyberPower CP425SLG uninterruptible power supply (UPS) 0.425 kVA, NEMA 5–20R on the CyberPower OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA.

  • Output power capacity
    • CP425SLG uninterruptible power supply (UPS) 0.425 kVA:0.425 kVA
    • OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA:2 kVA
  • Output power
    • CP425SLG uninterruptible power supply (UPS) 0.425 kVA:255 W
    • OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA:1320 W
  • Surge energy rating
    • CP425SLG uninterruptible power supply (UPS) 0.425 kVA:890 J
    • OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA:2060 J
  • AC outlet types
    • CP425SLG uninterruptible power supply (UPS) 0.425 kVA:NEMA 5–15R
    • OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA:NEMA 5–20R
  • Modem (RJ-11) ports
    • CP425SLG uninterruptible power supply (UPS) 0.425 kVA:1
    • OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA:2
  • Typical backup time at full load
    • CP425SLG uninterruptible power supply (UPS) 0.425 kVA:2 min
    • OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA:8 min
  • Typical backup time at half load
    • CP425SLG uninterruptible power supply (UPS) 0.425 kVA:7 min
    • OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA:20 min
  • Hot-swap battery
    • CP425SLG uninterruptible power supply (UPS) 0.425 kVA:No
    • OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA:Yes

Side by side

Differences highlightedShow differences only (on)
Comparison of CP425SLG, OR2200PFCRT2U
41 specifications
Features3 differ
Output power capacityDiffers0.425 kVA2 kVA
Output powerDiffers255 W1320 W
Surge energy ratingDiffers890 J2060 J
Response timeKnown for oneUnknown — not stated by the source4 ms
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Input frequencyKnown for one50/60 HzUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesDiffersNEMA 5–15RNEMA 5–20R
RS-232 portsKnown for oneUnknown — not stated by the source2
Modem (RJ-11) portsDiffers12
Serial ports quantityKnown for one0Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one0Unknown — not stated by the source
Battery3 differ
Typical backup time at full loadDiffers2 min8 min
Typical backup time at half loadDiffers7 min20 min
Hot-swap batteryDiffersNoYes
Design2 differ
Form factorDiffersCompactRackmount/Tower
Rack capacityKnown for oneUnknown — not stated by the source2U
Cable lengthDiffers1.52 m3 m
Display typeKnown for oneUnknown — not stated by the sourceLCD
Certificatesidentical
CertificationKnown for oneUL1778, cUL 107.3, FCC DOC Class BUnknown — not stated by the source
Weight & dimensionsidentical
WidthKnown for oneUnknown — not stated by the source431.8 mm
DepthKnown for oneUnknown — not stated by the source388.6 mm
HeightKnown for oneUnknown — not stated by the source88.9 mm
WeightKnown for oneUnknown — not stated by the source27 kg
Other features2 differ
Battery typeDiffers12V/3.6AH12 V, 9 Ah
Management platformKnown for oneUnknown — not stated by the sourceSNMP, HTTP
Nominal input voltageDiffers96-140 V90-140 V
Overload protectionKnown for oneUnknown — not stated by the sourceYes
Dimensions (W x D x H) (imperial)Known for one247.7 x 76.2 x 152.4 mm (9.75 x 3 x 6")Unknown — not stated by the source
Weight (imperial)Known for one2.27 kg (5 lbs)Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 35 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 90%Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons