Product comparison · 2 uninterruptible power supplies (upss)

CyberPower CP425SLG uninterruptible power supply (UPS) 0.425 kVA vs CyberPower OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA

Add a product
  • 21specifications compared
  • 12differ
  • 9identical
  • 20known for one product only

Key differences

The CyberPower OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA has 1.575 kVA more output power capacity than the CyberPower CP425SLG uninterruptible power supply (UPS) 0.425 kVA (2 kVA vs 0.425 kVA). The CyberPower OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA has 1,065 W more output power than the CyberPower CP425SLG uninterruptible power supply (UPS) 0.425 kVA (1320 W vs 255 W). The CyberPower OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA has 1,170 J more surge energy rating than the CyberPower CP425SLG uninterruptible power supply (UPS) 0.425 kVA (2060 J vs 890 J). Only the CyberPower OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA has hot-swap battery. AC outlet types: NEMA 5–15R on the CyberPower CP425SLG uninterruptible power supply (UPS) 0.425 kVA, NEMA 5–20R on the CyberPower OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA.

  • Output power capacity
    • CP425SLG uninterruptible power supply (UPS) 0.425 kVA:0.425 kVA
    • OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA:2 kVA
  • Output power
    • CP425SLG uninterruptible power supply (UPS) 0.425 kVA:255 W
    • OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA:1320 W
  • Surge energy rating
    • CP425SLG uninterruptible power supply (UPS) 0.425 kVA:890 J
    • OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA:2060 J
  • AC outlet types
    • CP425SLG uninterruptible power supply (UPS) 0.425 kVA:NEMA 5–15R
    • OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA:NEMA 5–20R
  • Modem (RJ-11) ports
    • CP425SLG uninterruptible power supply (UPS) 0.425 kVA:1
    • OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA:2
  • Typical backup time at full load
    • CP425SLG uninterruptible power supply (UPS) 0.425 kVA:2 min
    • OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA:8 min
  • Typical backup time at half load
    • CP425SLG uninterruptible power supply (UPS) 0.425 kVA:7 min
    • OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA:20 min
  • Hot-swap battery
    • CP425SLG uninterruptible power supply (UPS) 0.425 kVA:No
    • OR2200PFCRT2U uninterruptible power supply (UPS) 2 kVA:Yes

Side by side

Differences highlightedShow differences only (off)
Comparison of CP425SLG, OR2200PFCRT2U
41 specifications
Features3 differ
Output power capacityDiffers0.425 kVA2 kVA
Output powerDiffers255 W1320 W
Surge energy ratingDiffers890 J2060 J
Response timeKnown for oneUnknown — not stated by the source4 ms
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Audible alarm(s)YesYes
Input frequencyKnown for one50/60 HzUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesDiffersNEMA 5–15RNEMA 5–20R
AC outlets quantity8 AC outlet(s)8 AC outlet(s)
USB 2.0 ports quantity11
RS-232 portsKnown for oneUnknown — not stated by the source2
Modem (RJ-11) portsDiffers12
Serial ports quantityKnown for one0Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one0Unknown — not stated by the source
Battery3 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Typical backup time at full loadDiffers2 min8 min
Typical backup time at half loadDiffers7 min20 min
Battery recharge time8 h8 h
Hot-swap batteryDiffersNoYes
Design2 differ
Form factorDiffersCompactRackmount/Tower
Product colourBlackBlack
Rack capacityKnown for oneUnknown — not stated by the source2U
Cable lengthDiffers1.52 m3 m
Display typeKnown for oneUnknown — not stated by the sourceLCD
LED indicatorsYesYes
Certificatesidentical
Compliance certificatesRoHSRoHS
CertificationKnown for oneUL1778, cUL 107.3, FCC DOC Class BUnknown — not stated by the source
Weight & dimensionsidentical
WidthKnown for oneUnknown — not stated by the source431.8 mm
DepthKnown for oneUnknown — not stated by the source388.6 mm
HeightKnown for oneUnknown — not stated by the source88.9 mm
WeightKnown for oneUnknown — not stated by the source27 kg
Other features2 differ
Battery typeDiffers12V/3.6AH12 V, 9 Ah
Management platformKnown for oneUnknown — not stated by the sourceSNMP, HTTP
Nominal input voltageDiffers96-140 V90-140 V
Nominal output voltage120 V120 V
Overload protectionKnown for oneUnknown — not stated by the sourceYes
Dimensions (W x D x H) (imperial)Known for one247.7 x 76.2 x 152.4 mm (9.75 x 3 x 6")Unknown — not stated by the source
Weight (imperial)Known for one2.27 kg (5 lbs)Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 35 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 90%Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons