  • UPS topology
    • Li-504 500VA/250W UPS 4 Outlets, 1 USB A charger port Compact lithium based UPS 120 Vac:Standby (Offline)
    • UPO11-3RTAXi 3000VA/3000W Online UPS 2U 19' RT PF 1.0, LCD UL, FCC, CE 220 Vac:Double-conversion (Online)
  • Output power capacity
    • Li-504 500VA/250W UPS 4 Outlets, 1 USB A charger port Compact lithium based UPS 120 Vac:0.5 kVA
    • UPO11-3RTAXi 3000VA/3000W Online UPS 2U 19' RT PF 1.0, LCD UL, FCC, CE 220 Vac:3 kVA
  • Output power
    • Li-504 500VA/250W UPS 4 Outlets, 1 USB A charger port Compact lithium based UPS 120 Vac:250 W
    • UPO11-3RTAXi 3000VA/3000W Online UPS 2U 19' RT PF 1.0, LCD UL, FCC, CE 220 Vac:3000 W
  • Waveform
    • Li-504 500VA/250W UPS 4 Outlets, 1 USB A charger port Compact lithium based UPS 120 Vac:Sine
    • UPO11-3RTAXi 3000VA/3000W Online UPS 2U 19' RT PF 1.0, LCD UL, FCC, CE 220 Vac:Pure sine
  • Input operation voltage (min)
    • Li-504 500VA/250W UPS 4 Outlets, 1 USB A charger port Compact lithium based UPS 120 Vac:90 V
    • UPO11-3RTAXi 3000VA/3000W Online UPS 2U 19' RT PF 1.0, LCD UL, FCC, CE 220 Vac:110 V
  • Input operation voltage (max)
    • Li-504 500VA/250W UPS 4 Outlets, 1 USB A charger port Compact lithium based UPS 120 Vac:140 V
    • UPO11-3RTAXi 3000VA/3000W Online UPS 2U 19' RT PF 1.0, LCD UL, FCC, CE 220 Vac:300 V
  • Input frequency
    • Li-504 500VA/250W UPS 4 Outlets, 1 USB A charger port Compact lithium based UPS 120 Vac:50/60 Hz
    • UPO11-3RTAXi 3000VA/3000W Online UPS 2U 19' RT PF 1.0, LCD UL, FCC, CE 220 Vac:40 - 70 Hz
  • Output operation voltage (max)
    • Li-504 500VA/250W UPS 4 Outlets, 1 USB A charger port Compact lithium based UPS 120 Vac:115 V
    • UPO11-3RTAXi 3000VA/3000W Online UPS 2U 19' RT PF 1.0, LCD UL, FCC, CE 220 Vac:240 V

Side by side

Differences highlightedShow differences only (on)
Comparison of LI-504, UPO11-3RTAXI
75 specifications
Features10 differ
UPS topologyDiffersStandby (Offline)Double-conversion (Online)
Output power capacityDiffers0.5 kVA3 kVA
Output powerDiffers250 W3000 W
WaveformDiffersSinePure sine
Input operation voltage (min)Differs90 V110 V
Input operation voltage (max)Differs140 V300 V
Input frequencyDiffers50/60 Hz40 - 70 Hz
Output operation voltage (min)Known for oneUnknown — not stated by the source200 V
Output operation voltage (max)Differs115 V240 V
Surge energy ratingDiffers380 J844 J
Number of input phasesKnown for oneUnknown — not stated by the source1
Number of output phasesKnown for oneUnknown — not stated by the source1
Efficiency (On-line mode)Known for oneUnknown — not stated by the source90%
Efficiency (ECO mode)Known for oneUnknown — not stated by the source98%
Power factorKnown for oneUnknown — not stated by the source1
Input power factorKnown for oneUnknown — not stated by the source0.99
Output power factorKnown for oneUnknown — not stated by the source1
Crest factorKnown for oneUnknown — not stated by the source3:1
ECO modeKnown for oneUnknown — not stated by the sourceYes
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source4%
Input current Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source3%
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Noise levelDiffers45 dB50 dB
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload, Short circuit
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Response timeKnown for one2 msUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesDiffersNEMA 5-15RC13 coupler, C19 coupler
AC outlets quantityDiffers4 AC outlet(s)8 AC outlet(s)
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
RS-232 portsKnown for oneUnknown — not stated by the source1
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
USB port typeKnown for oneUSB Type-AUnknown — not stated by the source
Battery3 differ
Battery technologyDiffersLithium Iron Phosphate (LiFePO4)Lead-Acid
Battery capacityDiffers51.2 Wh9 Ah
Battery voltageDiffers12.8 V12 V
Number of batteries supportedKnown for oneUnknown — not stated by the source6
Typical backup time at full loadKnown for oneUnknown — not stated by the source7 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source15 min
Battery recharge timeKnown for oneUnknown — not stated by the source4 h
Cold startKnown for oneUnknown — not stated by the sourceYes
Battery recharge time(90%)Known for one6 hUnknown — not stated by the source
Design1 differ
Form factorDiffersMini TowerRackmount/Tower
Housing materialKnown for oneUnknown — not stated by the sourceMetal
Rack capacityKnown for oneUnknown — not stated by the source2U
Cable lengthKnown for oneUnknown — not stated by the source1.5 m
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Built-in fanKnown for oneUnknown — not stated by the sourceYes
Display typeKnown for oneUnknown — not stated by the sourceLCD
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP20
Operational conditions2 differ
Operating temperature (T-T)Differs0 - 50 °C0 - 40 °C
Storage temperature (T-T)Differs0 - 90 °C-15 - 60 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3000 m
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceNOM, ISO9001-2015, ISO14001, RETIE, TÜV, UL
Weight & dimensions4 differ
WidthDiffers125 mm600 mm
DepthDiffers182 mm760 mm
HeightDiffers47 mm200 mm
WeightDiffers880 g32.7 kg
Packaging data1 differ
Package weightDiffers990 g32.2 kg
Logistics data10 differ
Master (outer) case net weightDiffers19.8 kg32.7 kg
Pallet gross heightDiffers12 cm2.17 m
Pallet gross lengthDiffers114 cm120 cm
Pallet gross weightDiffers20 kg451.1 kg
Pallet gross widthDiffers110 cm100 cm
Master (outer) case widthDiffers280 mm600 mm
Master (outer) case lengthDiffers398 mm760 mm
Master (outer) case heightDiffers376 mm200 mm
Master (outer) case gross weightDiffers20.6 kg32.2 kg
Products per master (outer) caseDiffers20 pc(s)1 pc(s)