Product comparison · 2 uninterruptible power supplies (upss)

ATEN 230V 50/60Hz, 2000VA/2000W, 9Ah vs ATEN 230V 50/60Hz, 3000VA/3000W, 9Ah

Add a product
  • 63specifications compared
  • 21differ
  • 42identical
  • 1known for one product only

Key differences

The ATEN 230V 50/60Hz, 3000VA/3000W, 9Ah has 1 kVA more output power capacity than the ATEN 230V 50/60Hz, 2000VA/2000W, 9Ah (3 kVA vs 2 kVA). The ATEN 230V 50/60Hz, 3000VA/3000W, 9Ah has 1,000 W more output power than the ATEN 230V 50/60Hz, 2000VA/2000W, 9Ah (3000 W vs 2000 W). The ATEN 230V 50/60Hz, 3000VA/3000W, 9Ah has 1% more efficiency than the ATEN 230V 50/60Hz, 2000VA/2000W, 9Ah (90% vs 89%). AC outlet types: C13 coupler on the ATEN 230V 50/60Hz, 2000VA/2000W, 9Ah, C13 coupler, C19 coupler on the ATEN 230V 50/60Hz, 3000VA/3000W, 9Ah. Power plug: C13 coupler on the ATEN 230V 50/60Hz, 2000VA/2000W, 9Ah, C20 coupler on the ATEN 230V 50/60Hz, 3000VA/3000W, 9Ah.

  • Output power capacity
    • 230V 50/60Hz, 2000VA/2000W, 9Ah:2 kVA
    • 230V 50/60Hz, 3000VA/3000W, 9Ah:3 kVA
  • Output power
    • 230V 50/60Hz, 2000VA/2000W, 9Ah:2000 W
    • 230V 50/60Hz, 3000VA/3000W, 9Ah:3000 W
  • Efficiency
    • 230V 50/60Hz, 2000VA/2000W, 9Ah:89%
    • 230V 50/60Hz, 3000VA/3000W, 9Ah:90%
  • AC outlet types
    • 230V 50/60Hz, 2000VA/2000W, 9Ah:C13 coupler
    • 230V 50/60Hz, 3000VA/3000W, 9Ah:C13 coupler, C19 coupler
  • Power plug
    • 230V 50/60Hz, 2000VA/2000W, 9Ah:C13 coupler
    • 230V 50/60Hz, 3000VA/3000W, 9Ah:C20 coupler
  • AC outlets quantity
    • 230V 50/60Hz, 2000VA/2000W, 9Ah:8 AC outlet(s)
    • 230V 50/60Hz, 3000VA/3000W, 9Ah:9 AC outlet(s)
  • Battery voltage
    • 230V 50/60Hz, 2000VA/2000W, 9Ah:12 V
    • 230V 50/60Hz, 3000VA/3000W, 9Ah:72 V
  • Number of battery cells
    • 230V 50/60Hz, 2000VA/2000W, 9Ah:4
    • 230V 50/60Hz, 3000VA/3000W, 9Ah:6

Side by side

Differences highlightedShow differences only (on)
Comparison of OL2000HV-AT-G, OL3000HV-AT-G
64 specifications
Features3 differ
Output power capacityDiffers2 kVA3 kVA
Output powerDiffers2000 W3000 W
EfficiencyDiffers89%90%
Ports & interfaces3 differ
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Power plugDiffersC13 couplerC20 coupler
AC outlets quantityDiffers8 AC outlet(s)9 AC outlet(s)
Battery4 differ
Battery voltageDiffers12 V72 V
Number of batteries supportedKnown for oneUnknown — not stated by the source6
Number of battery cellsDiffers46
Typical backup time at full loadDiffers2.95 min2.96 min
Typical backup time at half loadDiffers10 min10.1 min
Weight & dimensions4 differ
WidthDiffers88 mm438 mm
DepthDiffers438 mm88 mm
HeightDiffers510 mm630 mm
WeightDiffers19.9 kg27.6 kg
Packaging data2 differ
Package heightDiffers510 mm630 mm
Package weightDiffers25.9 kg34.8 kg
Logistics data5 differ
Master (outer) case net weightDiffers19.9 kg27.6 kg
Master (outer) case widthDiffers240 mm600 mm
Master (outer) case lengthDiffers565 mm760 mm
Master (outer) case heightDiffers700 mm240 mm
Master (outer) case gross weightDiffers25.9 kg34.8 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons