Product comparison · 2 uninterruptible power supplies (upss)

ATEN OL1000HV uninterruptible power supply (UPS) Double-conversion (Online) vs ATEN OL3000HV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA

Add a product
  • 36specifications compared
  • 11differ
  • 25identical
  • 29known for one product only

Key differences

  • Output power
    • OL1000HV uninterruptible power supply (UPS) Double-conversion (Online):1000 W
    • OL3000HV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3000 W
  • Maximum current
    • OL1000HV uninterruptible power supply (UPS) Double-conversion (Online):4.8 A
    • OL3000HV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:14.5 A
  • AC outlets quantity
    • OL1000HV uninterruptible power supply (UPS) Double-conversion (Online):8 AC outlet(s)
    • OL3000HV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:9 AC outlet(s)
  • Number of batteries supported
    • OL1000HV uninterruptible power supply (UPS) Double-conversion (Online):2
    • OL3000HV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:6
  • Charging current
    • OL1000HV uninterruptible power supply (UPS) Double-conversion (Online):12 A
    • OL3000HV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:8 A
  • Storage relative humidity (H-H)
    • OL1000HV uninterruptible power supply (UPS) Double-conversion (Online):10 - 95%
    • OL3000HV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:-20 - 50%
  • Width
    • OL1000HV uninterruptible power supply (UPS) Double-conversion (Online):880 mm
    • OL3000HV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:438 mm
  • Depth
    • OL1000HV uninterruptible power supply (UPS) Double-conversion (Online):438 mm
    • OL3000HV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:88 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of OL1000HV, OL3000HV
65 specifications
Features2 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output powerDiffers1000 W3000 W
WaveformSineSine
Input operation voltage (min)110 V110 V
Input operation voltage (max)300 V300 V
Input frequency40/70 Hz40/70 Hz
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
Output voltage regulationKnown for one1%Unknown — not stated by the source
Maximum currentDiffers4.8 A14.5 A
Response timeKnown for one0 msUnknown — not stated by the source
EfficiencyKnown for one97%Unknown — not stated by the source
Input power factorKnown for one0.99Unknown — not stated by the source
Output power factorKnown for one1Unknown — not stated by the source
Crest factor3:13:1
ECO modeYesYes
Emergency Power Off (EPO)YesYes
Noise level50 dB50 dB
Output power capacityKnown for oneUnknown — not stated by the source3 kVA
Power factorKnown for oneUnknown — not stated by the source1
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source4%
Power protection featuresKnown for oneUnknown — not stated by the sourceOver voltage
Ports & interfaces1 differ
AC outlet typesKnown for oneC14 coupler, IEC 320Unknown — not stated by the source
Power plugKnown for oneC13 couplerUnknown — not stated by the source
AC outlets quantityDiffers8 AC outlet(s)9 AC outlet(s)
USB portYesYes
Serial interfaceKnown for oneYesUnknown — not stated by the source
Serial interface typeKnown for oneRS-232Unknown — not stated by the source
Emergency Power Off (EPO) connectorYesYes
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
USB port typeKnown for oneUnknown — not stated by the sourceUSB Type-B
RS-232 portsKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Battery2 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Battery capacity9 Ah9 Ah
Battery voltage12 V12 V
Number of batteries supportedDiffers26
Typical backup time at full loadKnown for one2.95 minUnknown — not stated by the source
Typical backup time at half loadKnown for one10.1 minUnknown — not stated by the source
Charging currentDiffers12 A8 A
Hot-swap batteryYesYes
Cold startYesYes
Replacement battery cartridgeKnown for one1Unknown — not stated by the source
Battery recharge timeKnown for oneUnknown — not stated by the source3 h
Designidentical
Form factorRackmount/TowerRackmount/Tower
Product colourBlackBlack
Rack capacity2U2U
Cable lengthKnown for one1.8 mUnknown — not stated by the source
Cooling typeKnown for oneActiveUnknown — not stated by the source
Built-in fanKnown for oneYesUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-20 - 50 °C-20 - 50 °C
Operating relative humidity (H-H)20 - 90%20 - 90%
Storage relative humidity (H-H)Differs10 - 95%-20 - 50%
Packaging content1 differ
Rack mount kitYesYes
Cables includedDiffersPower load cable, RS-232, USB cablePower load cable, USB cable
ManualKnown for oneYesUnknown — not stated by the source
Certificatesidentical
Compliance certificatesRoHSRoHS
CertificationKnown for oneCEUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers880 mm438 mm
DepthDiffers438 mm88 mm
HeightDiffers410 mm63 mm
WeightDiffers12.7 kg28.7 kg
Logistics dataidentical
Harmonized System (HS) code8507800085078000

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.