Product comparison · 2 uninterruptible power supplies (upss)

ATEN 230V 50/60Hz, 1000VA/1000W, 9Ah vs ATEN OL2000HV uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA

Add a product
  • 42specifications compared
  • 13differ
  • 29identical
  • 39known for one product only

Key differences

The ATEN OL2000HV uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA has 0.5 kVA more output power capacity than the ATEN 230V 50/60Hz, 1000VA/1000W, 9Ah (1.5 kVA vs 1 kVA). The ATEN OL2000HV uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA has 500 W more output power than the ATEN 230V 50/60Hz, 1000VA/1000W, 9Ah (1500 W vs 1000 W). The ATEN 230V 50/60Hz, 1000VA/1000W, 9Ah has 4 ms more response time than the ATEN OL2000HV uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA (4 ms vs 0 ms). Input frequency: 40 - 70 Hz on the ATEN 230V 50/60Hz, 1000VA/1000W, 9Ah, 40/70 Hz on the ATEN OL2000HV uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA. Certification: CE RoHS on the ATEN 230V 50/60Hz, 1000VA/1000W, 9Ah, CE on the ATEN OL2000HV uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA.

  • Output power capacity
    • 230V 50/60Hz, 1000VA/1000W, 9Ah:1 kVA
    • OL2000HV uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:1.5 kVA
  • Output power
    • 230V 50/60Hz, 1000VA/1000W, 9Ah:1000 W
    • OL2000HV uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:1500 W
  • Input frequency
    • 230V 50/60Hz, 1000VA/1000W, 9Ah:40 - 70 Hz
    • OL2000HV uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:40/70 Hz
  • Response time
    • 230V 50/60Hz, 1000VA/1000W, 9Ah:4 ms
    • OL2000HV uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:0 ms
  • Efficiency
    • 230V 50/60Hz, 1000VA/1000W, 9Ah:88%
    • OL2000HV uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:97%
  • Typical backup time at full load
    • 230V 50/60Hz, 1000VA/1000W, 9Ah:2.95 min
    • OL2000HV uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:2.96 min
  • Typical backup time at half load
    • 230V 50/60Hz, 1000VA/1000W, 9Ah:10.1 min
    • OL2000HV uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:10.3 min
  • Certification
    • 230V 50/60Hz, 1000VA/1000W, 9Ah:CE RoHS
    • OL2000HV uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:CE

Side by side

Differences highlightedShow differences only (on)
Comparison of OL1000HV-AT-G, OL2000HV
81 specifications
Features5 differ
Output power capacityDiffers1 kVA1.5 kVA
Output powerDiffers1000 W1500 W
Input frequencyDiffers40 - 70 Hz40/70 Hz
Output operation voltage (min)Known for one220 VUnknown — not stated by the source
Output operation voltage (max)Known for one240 VUnknown — not stated by the source
Response timeDiffers4 ms0 ms
EfficiencyDiffers88%97%
Efficiency (ECO mode)Known for one96%Unknown — not stated by the source
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Output voltage regulationKnown for oneUnknown — not stated by the source1%
Maximum currentKnown for oneUnknown — not stated by the source7.2 A
Input power factorKnown for oneUnknown — not stated by the source0.99
Output power factorKnown for oneUnknown — not stated by the source1
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source2%
Power protection featuresKnown for oneUnknown — not stated by the sourceOver voltage
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Ports & interfacesidentical
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
USB port typeKnown for oneUSB Type-BUnknown — not stated by the source
Serial interface typeKnown for oneRS-232Unknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one2Unknown — not stated by the source
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
Battery2 differ
Number of battery cellsKnown for one2Unknown — not stated by the source
Typical backup time at full loadDiffers2.95 min2.96 min
Typical backup time at half loadDiffers10.1 min10.3 min
Charging currentKnown for one2 AUnknown — not stated by the source
Number of batteries supportedKnown for oneUnknown — not stated by the source3
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceBC36V9AH
Designidentical
Built-in fanKnown for oneYesUnknown — not stated by the source
Cable lengthKnown for oneUnknown — not stated by the source1.8 m
Display typeKnown for oneUnknown — not stated by the sourceLCD
Packaging content1 differ
Cables includedDiffersOutput power cable, Power load cable, RS-232, USB cableInput power cable, RS-232, USB cable
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Quick installation guideKnown for oneUnknown — not stated by the sourceYes
Certificates1 differ
CertificationDiffersCE RoHSCE
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Weight & dimensions4 differ
WidthDiffers88 mm438 mm
DepthDiffers438 mm410 mm
HeightDiffers410 mm88 mm
WeightDiffers13.4 kg14.3 kg
Packaging dataidentical
Package widthKnown for one88 mmUnknown — not stated by the source
Package depthKnown for one438 mmUnknown — not stated by the source
Package heightKnown for one410 mmUnknown — not stated by the source
Package weightKnown for one18.5 kgUnknown — not stated by the source
Logistics dataidentical
Master (outer) case net weightKnown for one13.4 kgUnknown — not stated by the source
Master (outer) case widthKnown for one240 mmUnknown — not stated by the source
Master (outer) case lengthKnown for one500 mmUnknown — not stated by the source
Master (outer) case heightKnown for one600 mmUnknown — not stated by the source
Master (outer) case gross weightKnown for one18.5 kgUnknown — not stated by the source
Products per master (outer) caseKnown for one1 pc(s)Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.