Product comparison · 2 uninterruptible power supplies (upss)

APC Symmetra PX 125kW Scalable to 250kW w/o Bypass, Distribution or Batteries-Parallel Capable vs CyberPower PR2200LCDRT2UTAA uninterruptible power supply (UPS) 2.17 kVA

Add a product
  • 22specifications compared
  • 18differ
  • 4identical
  • 42known for one product only

Key differences

The APC Symmetra PX 125kW Scalable to 250kW w/o Bypass, Distribution or Batteries-Parallel Capable has 497.83 kVA more output power capacity than the CyberPower PR2200LCDRT2UTAA uninterruptible power supply (UPS) 2.17 kVA (500 kVA vs 2.17 kVA). The APC Symmetra PX 125kW Scalable to 250kW w/o Bypass, Distribution or Batteries-Parallel Capable has 498,400 W more output power than the CyberPower PR2200LCDRT2UTAA uninterruptible power supply (UPS) 2.17 kVA (500000 W vs 1600 W). The APC Symmetra PX 125kW Scalable to 250kW w/o Bypass, Distribution or Batteries-Parallel Capable has 320 V more input operation voltage (min) than the CyberPower PR2200LCDRT2UTAA uninterruptible power supply (UPS) 2.17 kVA (400 V vs 80 V). Input frequency: 40/70 Hz on the APC Symmetra PX 125kW Scalable to 250kW w/o Bypass, Distribution or Batteries-Parallel Capable, 50/60 Hz on the CyberPower PR2200LCDRT2UTAA uninterruptible power supply (UPS) 2.17 kVA. Audible alarm modes: Alarm when on battery, Low battery alarm on the APC Symmetra PX 125kW Scalable to 250kW w/o Bypass, Distribution or Batteries-Parallel Capable, Battery replacement on the CyberPower PR2200LCDRT2UTAA uninterruptible power supply (UPS) 2.17 kVA.

  • Output power capacity
    • Symmetra PX 125kW Scalable to 250kW w/o Bypass, Distribution or Batteries-Parallel Capable:500 kVA
    • PR2200LCDRT2UTAA uninterruptible power supply (UPS) 2.17 kVA:2.17 kVA
  • Output power
    • Symmetra PX 125kW Scalable to 250kW w/o Bypass, Distribution or Batteries-Parallel Capable:500000 W
    • PR2200LCDRT2UTAA uninterruptible power supply (UPS) 2.17 kVA:1600 W
  • Input operation voltage (min)
    • Symmetra PX 125kW Scalable to 250kW w/o Bypass, Distribution or Batteries-Parallel Capable:400 V
    • PR2200LCDRT2UTAA uninterruptible power supply (UPS) 2.17 kVA:80 V
  • Input operation voltage (max)
    • Symmetra PX 125kW Scalable to 250kW w/o Bypass, Distribution or Batteries-Parallel Capable:552 V
    • PR2200LCDRT2UTAA uninterruptible power supply (UPS) 2.17 kVA:150 V
  • Input frequency
    • Symmetra PX 125kW Scalable to 250kW w/o Bypass, Distribution or Batteries-Parallel Capable:40/70 Hz
    • PR2200LCDRT2UTAA uninterruptible power supply (UPS) 2.17 kVA:50/60 Hz
  • Output operation voltage (min)
    • Symmetra PX 125kW Scalable to 250kW w/o Bypass, Distribution or Batteries-Parallel Capable:400 V
    • PR2200LCDRT2UTAA uninterruptible power supply (UPS) 2.17 kVA:120 V
  • Output operation voltage (max)
    • Symmetra PX 125kW Scalable to 250kW w/o Bypass, Distribution or Batteries-Parallel Capable:480 V
    • PR2200LCDRT2UTAA uninterruptible power supply (UPS) 2.17 kVA:120 V
  • Form factor
    • Symmetra PX 125kW Scalable to 250kW w/o Bypass, Distribution or Batteries-Parallel Capable:Tower
    • PR2200LCDRT2UTAA uninterruptible power supply (UPS) 2.17 kVA:Rackmount/Tower

Side by side

Differences highlightedShow differences only (on)
Comparison of SY125K250D-NB, PR2200LCDRT2UTAA
64 specifications
Features8 differ
UPS topologyKnown for oneDouble-conversion (Online)Unknown — not stated by the source
Output power capacityDiffers500 kVA2.17 kVA
Output powerDiffers500000 W1600 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Differs400 V80 V
Input operation voltage (max)Differs552 V150 V
Input frequencyDiffers40/70 Hz50/60 Hz
Output operation voltage (min)Differs400 V120 V
Output operation voltage (max)Differs480 V120 V
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
Response timeKnown for one2 msUnknown — not stated by the source
Number of input phasesKnown for one3Unknown — not stated by the source
Number of output phasesKnown for one3Unknown — not stated by the source
EfficiencyKnown for one96%Unknown — not stated by the source
Input power factorKnown for one0.99Unknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one3%Unknown — not stated by the source
Input current Total Harmonic Distortion (THD)Known for one5%Unknown — not stated by the source
Noise levelKnown for one54 dBUnknown — not stated by the source
Power protection featuresKnown for oneOverload, Short circuitUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesDiffersAlarm when on battery, Low battery alarmBattery replacement
Surge energy ratingKnown for oneUnknown — not stated by the source1780 J
Ports & interfaces1 differ
AC outlet typesDiffersHard Wire 4-wire (3PH + G), Hard Wire 5-wire (3PH + N + G)NEMA 5–20P
RS-232 portsKnown for one1Unknown — not stated by the source
SmartSlotKnown for oneYesUnknown — not stated by the source
AC outlets quantityKnown for oneUnknown — not stated by the source8 AC outlet(s)
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Serial ports quantityKnown for oneUnknown — not stated by the source2
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source2
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Design2 differ
Form factorDiffersTowerRackmount/Tower
LED indicatorsDiffersYesPower, Power fail
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Rack capacityKnown for oneUnknown — not stated by the source2U
Cable lengthKnown for oneUnknown — not stated by the source3.05 m
Operational conditions2 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 35 °C
Storage temperature (T-T)Known for one-30 - 70 °CUnknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeDiffers0 - 1000 m0 - 3000 m
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Quick installation guideKnown for oneYesUnknown — not stated by the source
Certificates1 differ
CertificationDifferscUL Listed, CSA C22.2 No.107.3-05, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, OSHPD, UL 1778, UL 60950-1, UL ListedUL1778, cUL 107.1, FCC DOC B
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Weight & dimensions4 differ
WidthDiffers1200 mm438 mm
DepthDiffers1070 mm400 mm
HeightDiffers1991 mm44 mm
WeightDiffers864 kg28.6 kg
Packaging dataidentical
Package widthKnown for one1870 mmUnknown — not stated by the source
Package depthKnown for one1270 mmUnknown — not stated by the source
Package heightKnown for one2150 mmUnknown — not stated by the source
Package weightKnown for one1000 kgUnknown — not stated by the source
Bundled softwareKnown for oneUnknown — not stated by the sourcePowerPanel Business Edition
Batteryidentical
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Number of battery cellsKnown for oneUnknown — not stated by the source4
Typical backup time at full loadKnown for oneUnknown — not stated by the source6 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source16 min
Battery recharge timeKnown for oneUnknown — not stated by the source8 h
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceBB Battery - HR9-12
Other featuresidentical
Number of phasesKnown for oneUnknown — not stated by the source1
Battery typeKnown for oneUnknown — not stated by the source12V/9AH

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.