Product comparison · 2 uninterruptible power supplies (upss)

APC SURT20KRMXLI + WBEXTWAR3YR-SP-08 vs CyberPower OL10000RT3UTF uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA

Add a product
  • 31specifications compared
  • 19differ
  • 12identical
  • 29known for one product only

Key differences

  • Output power capacity
    • SURT20KRMXLI + WBEXTWAR3YR-SP-08:20 kVA
    • OL10000RT3UTF uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:10 kVA
  • Output power
    • SURT20KRMXLI + WBEXTWAR3YR-SP-08:16000 W
    • OL10000RT3UTF uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:9000 W
  • Input operation voltage (min)
    • SURT20KRMXLI + WBEXTWAR3YR-SP-08:230 V
    • OL10000RT3UTF uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:120 V
  • Input operation voltage (max)
    • SURT20KRMXLI + WBEXTWAR3YR-SP-08:230 V
    • OL10000RT3UTF uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:280 V
  • Input frequency
    • SURT20KRMXLI + WBEXTWAR3YR-SP-08:40 - 70 Hz
    • OL10000RT3UTF uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:40/70 Hz
  • Output operation voltage (min)
    • SURT20KRMXLI + WBEXTWAR3YR-SP-08:230 V
    • OL10000RT3UTF uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:200 V
  • Output operation voltage (max)
    • SURT20KRMXLI + WBEXTWAR3YR-SP-08:230 V
    • OL10000RT3UTF uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:240 V
  • AC outlets quantity
    • SURT20KRMXLI + WBEXTWAR3YR-SP-08:12 AC outlet(s)
    • OL10000RT3UTF uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:19 AC outlet(s)

Side by side

Differences highlightedShow differences only (off)
Comparison of SURT20KRMXLI + WBEXTWAR3YR-SP-08, OL10000RT3UTF
60 specifications
Features7 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers20 kVA10 kVA
Output powerDiffers16000 W9000 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Differs230 V120 V
Input operation voltage (max)Differs230 V280 V
Input frequencyDiffers40 - 70 Hz40/70 Hz
Output operation voltage (min)Differs230 V200 V
Output operation voltage (max)Differs230 V240 V
Output frequency regulationKnown for one47/63 HzUnknown — not stated by the source
Output voltage regulationKnown for one5%Unknown — not stated by the source
Maximum currentKnown for one105 AUnknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Noise levelKnown for one59 dBUnknown — not stated by the source
Power protection featuresOverloadOverload
Audible alarm(s)Known for oneYesUnknown — not stated by the source
EfficiencyKnown for oneUnknown — not stated by the source95%
Crest factorKnown for oneUnknown — not stated by the source3:1
Input current Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source5%
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlet typesDiffersC19 couplerNEMA 5–20R, NEMA L6-20R, NEMA L6-30R
AC outlets quantityDiffers12 AC outlet(s)19 AC outlet(s)
Number of output IEC jumpersKnown for one2Unknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Serial ports quantity11
Ethernet LAN (RJ-45) ports11
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source1
Battery3 differ
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Typical backup time at full loadDiffers4.9 min4 min
Typical backup time at half loadDiffers15.3 min11 min
Battery recharge timeDiffers2.5 h5 h
Battery capacityKnown for oneUnknown — not stated by the source9 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Number of batteries supportedKnown for oneUnknown — not stated by the source20
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Cold startKnown for oneUnknown — not stated by the sourceYes
Design1 differ
Form factorRackmountRackmount
Product colourBlackBlack
Rack capacityDiffers12U9U
LED indicatorsYesYes
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Display typeKnown for oneUnknown — not stated by the sourceLCD
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-15 - 45 °C-15 - 45 °C
Operating relative humidity (H-H)Differs0 - 95%0 - 90%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitude0 - 15000 m0 - 15000 m
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDiffersBSMI, EN/IEC 62040-2, EN/IEC 62040-1-1, VDEUL, CSA, FCC DOC
Weight & dimensions4 differ
WidthDiffers432 mm433 mm
DepthDiffers773 mm660 mm
HeightDiffers533 mm400 mm
WeightDiffers247.7 kg174.6 kg
Packaging dataidentical
Package widthKnown for one610 mmUnknown — not stated by the source
Package depthKnown for one1003 mmUnknown — not stated by the source
Package heightKnown for one990 mmUnknown — not stated by the source
Package weightKnown for one314.1 kgUnknown — not stated by the source
Other featuresidentical
Battery typeKnown for oneUnknown — not stated by the sourceRB1290X20

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.